Two-layer sample preparation: A method for MALDI-MS analysis of complex peptide and protein mixtures

被引:178
作者
Dai, YQ [1 ]
Whittal, RM [1 ]
Li, L [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
关键词
D O I
10.1021/ac980684h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical performance of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry for direct analysis of peptide and protein mixtures is strongly dependent on the sample and matrix preparation. A two-layer sample preparation method is demonstrated to be very effective for analyzing complex mixtures. In this method, the first layer on the MALDI probe is the densely packed matrix microcrystals formed by fast solvent evaporation of a matrix solution. A mixture solution containing both matrix and sample is then deposited onto the first layer to form uniform analyte/matrix micrococrystals. It is found that the addition of matrix to the second-layer sample solution proves to be critical in analyzing mixtures of peptides and proteins covering a broad mass range. The effect of solvent conditions for preparing the second-layer solution is discussed. The application of this method is demonstrated for the analysis of cow's milk where milk proteins as well as peptide fragments produced from proteins by indigenous proteinases are detected. Direct analyses of peptides and proteins from a bacteria extract and crude egg white are also illustrated.
引用
收藏
页码:1087 / 1091
页数:5
相关论文
共 28 条
  • [1] MATRIX-ASSISTED LASER DESORPTION/IONIZATION USING AN ACTIVE PERFLUOROSULFONATED IONOMER FILM SUBSTRATE
    BAI, J
    LIU, YH
    CAIN, TC
    LUBMAN, DM
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (20) : 3423 - 3430
  • [2] TRYPTIC MAPPING OF RECOMBINANT PROTEINS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY
    BILLECI, TM
    STULTS, JT
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (13) : 1709 - 1716
  • [3] Catinella S, 1996, RAPID COMMUN MASS SP, V10, P1123
  • [4] Catinella S, 1996, RAPID COMMUN MASS SP, V10, P1629, DOI 10.1002/(SICI)1097-0231(199610)10:13<1629::AID-RCM655>3.0.CO
  • [5] 2-B
  • [6] Influence of matrix solution conditions on the MALDI-MS analysis of peptides and proteins
    Cohen, SL
    Chait, BT
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (01) : 31 - 37
  • [7] Confocal fluorescence microscopic imaging for investigating the analyte distribution in MALDI matrices
    Dai, YQ
    Whittal, RM
    Li, L
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (15) : 2494 - 2500
  • [8] DAI YQ, IN PRESS RAPID COMMU
  • [9] FOX PF, 1995, ADV EXP MED BIOL, V367, P59
  • [10] IMPROVEMENT OF SIGNAL REPRODUCIBILITY AND MATRIX/COMATRIX EFFECTS IN MALDI ANALYSIS
    GUSEV, AI
    WILKINSON, WR
    PROCTOR, A
    HERCULES, DM
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (06) : 1034 - 1041