A poly(o-aminophenol) modified electrode as an amperometric hydrogen peroxide biosensor

被引:52
作者
Garcia, MAV
Blanco, PT [1 ]
Ivaska, A
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Oviedo 33006, Asturias, Spain
[2] Abo Akad Univ, Analyt Chem Lab, SF-20500 Turku, Finland
关键词
enzymatic biosensor; hydrogen peroxide; poly(o-aminophenol) films; amperometric; flow injection analysis;
D O I
10.1016/S0013-4686(98)00101-7
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
An enzymatic biosensor for hydrogen peroxide based on a horseradish peroxidase (HRP)-ferrocene carbon paste modified electrode and coated with a layer of electrochemically generated poly(o-aminophenol) is reported. A linear calibration curve is obtained over the range 1 x 10(-8) M to 1 x 10(-5) M. The biosensor responds to hydrogen peroxide ina few seconds and has a detection limit of 8.5 x 10(-9) M. The response of the biosensor is diffusion controlled at low substrate concentrations. Flow injection assays of hydrogen peroxide at a sampling rate of 150 injections per hour with a relative standard deviation of 0.8% (50 samples) are possible. Applicability of the sensor for measurement of hydrogen peroxide in real samples (milk) was demonstrated. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:3533 / 3539
页数:7
相关论文
共 36 条
[1]  
ALVAREZICAZA M, 1993, ANAL CHEM, V65, P525
[2]   FORMATION OF A NOVEL ELECTROACTIVE FILM BY ELECTROPOLYMERIZATION OF ORTHO-AMINOPHENOL - STUDY OF ITS CHEMICAL-STRUCTURE AND FORMATION MECHANISM - ELECTROPOLYMERIZATION OF ANALOGOUS COMPOUNDS [J].
BARBERO, C ;
SILBER, JJ ;
SERENO, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 263 (02) :333-352
[3]   ELECTROCHEMICAL PROPERTIES OF POLY-ORTHO-AMINOPHENOL MODIFIED ELECTRODES IN AQUEOUS ACID-SOLUTIONS [J].
BARBERO, C ;
SILBER, JJ ;
SERENO, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 291 (1-2) :81-101
[4]   ELECTROCHEMICAL TRANSFORMATIONS OF PROTEINS ADSORBED AT CARBON ELECTRODES [J].
BOGDANOVSKAYA, VA ;
TARASEVICH, MR ;
HINTSCHE, R ;
SCHELLER, F .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1988, 19 (03) :581-584
[5]  
CASTANON JL, 1997, ANAL CHIM ACTA, V346, P165, DOI DOI 10.1016/S0003-2670(97)00115-3
[6]   CHEMICALLY IMMOBILIZED ENZYME ELECTRODES FOR HYDROGEN-PEROXIDE DETERMINATION [J].
COSGROVE, M ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1988, 113 (12) :1811-1815
[7]   CARBON-FIBERS AS ELECTRODE MATERIALS FOR THE CONSTRUCTION OF PEROXIDASE-MODIFIED AMPEROMETRIC BIOSENSORS [J].
CSOREGI, E ;
GORTON, L ;
MARKOVARGA, G .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :59-70
[8]   MEDIATORLESS HYDROGEN-PEROXIDE ELECTRODE BASED ON HORSERADISH-PEROXIDASE ENTRAPPED IN POLY(O-PHENYLENEDIAMINE) [J].
DENG, Q ;
DONG, SJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 377 (1-2) :191-195
[9]  
DOMINGUEZSANCHE.P, 1991, ELECTROANAL, V3, P281
[10]   A METHOD FOR ESTIMATION OF HYDROGEN-PEROXIDE BASED ON MEDIATED ELECTRON-TRANSFER REACTIONS OF PEROXIDASES AT ELECTRODES [J].
FREW, JE ;
HARMER, MA ;
HILL, HAO ;
LIBOR, SI .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 201 (01) :1-10