An immunoassay for Leu-enkephalin based on a C-terminal aequorin-peptide fusion

被引:21
作者
Deo, SK [1 ]
Daunert, S [1 ]
机构
[1] Univ Kentucky, Dept Chem, Lexington, KY 40506 USA
关键词
D O I
10.1021/ac001100q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently we demonstrated that the fusion of an octapeptide to the C-terminus of a cysteine-free mutant of aequorin showed no inhibitory effect on the luminescence activity of the photoprotein, This observation is of particular importance when the use of aequorin as a label in the development of immunoassays for peptides whose activity lies in their C-terminal region or the epitope for antibody recognition is at their C-terminus is desired. In the case of opioid peptides, antibodies are directed toward their C-terminus as they differ from each other at this terminus. The goal of this study was to develop an immunoassay for Leu-enkephalin, a mammalian opioid peptide, using a C-terminal aequorin-peptide fusion protein. For that, the N-terminus of Leu-enkephalin was genetically fused to the C-terminus of a cysteine-free mutant of aequorin. It was observed that the C-terminal conjugated aequorin maintained its luminescence activity. An immunoassay for Leu-enkephalin was then developed using the aequorin-Leu-enkephalin fusion protein as a labeled analyte in a competitive as well as in a sequential binding mode, It was demonstrated that aequorin can be used as a label in peptide assays in which it is critical that the peptide's C-terminus be free for activity and/or for antibody recognition.
引用
收藏
页码:1903 / 1908
页数:6
相关论文
共 33 条
[1]   A flash-type bioluminescent immunoassay that is more sensitive than radioimaging: quantitative detection of cytokine cDNA in activated and resting human cells [J].
Actor, JK ;
Kuffner, T ;
Dezzutti, CS ;
Hunter, RL ;
McNicholl, JM .
JOURNAL OF IMMUNOLOGICAL METHODS, 1998, 211 (1-2) :65-77
[2]   SUSCEPTIBILITY OF NEUROACTIVE PEPTIDES TO AMINOPEPTIDASE DIGESTION IS RELATED TO MOLECULAR-SIZE [J].
AUSTEN, BM ;
EVANS, CJ ;
SMYTH, DG .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1979, 91 (04) :1211-1217
[3]  
Brini M, 1999, MICROSC RES TECHNIQ, V46, P380, DOI 10.1002/(SICI)1097-0029(19990915)46:6<380::AID-JEMT6>3.0.CO
[4]  
2-Y
[5]   PRIMARY STRUCTURE OF THE HUMAN MET-ENKEPHALIN AND LEU-ENKEPHALIN PRECURSOR AND ITS MESSENGER-RNA [J].
COMB, M ;
SEEBURG, PH ;
ADELMAN, J ;
EIDEN, L ;
HERBERT, E .
NATURE, 1982, 295 (5851) :663-666
[6]   ENKEPHALINS AND ENDORPHINS - CLINICAL, PHARMACOLOGICAL AND THERAPEUTIC IMPLICATIONS [J].
COPOLOV, DL ;
HELME, RD .
DRUGS, 1983, 26 (06) :503-519
[7]   Detecting biomolecules in picoliter vials using aequorin bioluminescence [J].
Crofcheck, CL ;
Grosvenor, AL ;
Anderson, KW ;
Lumpp, JK ;
Scott, DL ;
Daunert, S .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4768-4772
[8]   ISOCRATIC REVERSE-PHASE HPLC SEPARATION AND RIA USED IN THE ANALYSIS OF NEUROPEPTIDES IN BRAIN-TISSUE [J].
DECEBALLOS, ML ;
TAYLOR, MD ;
JENNER, P .
NEUROPEPTIDES, 1991, 20 (03) :201-209
[9]   Bioluminescence detection of proteolytic bond cleavage by using recombinant aequorin [J].
Deo, SK ;
Lewis, JD ;
Daunert, S .
ANALYTICAL BIOCHEMISTRY, 2000, 281 (01) :87-94
[10]  
DEO SK, 2000, 219 ACS NAT M