PH sensitivity of novel PANI/PVB/PS3 composite films

被引:32
作者
Gill, Edric [1 ]
Arshak, Arousian [1 ]
Arshak, Khalil [2 ]
Korostynska, Olga [2 ]
机构
[1] Univ Limerick, Dept Phys, Limerick, Ireland
[2] Univ Limerick, Dept Elect & Comp Engn, Limerick, Ireland
关键词
PANI composite film; XPS; thick films; conductance; interdigitated electrodes;
D O I
10.3390/s7123329
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports on the results from the investigation into the pH sensitivity of novel PANI/PVB/PS3 composite films. The conductimetric sensing mode was chosen as it is one of the most promising alternatives to the mainstream pH-sensing methods and it is the least investigated due to the popularity of other approaches. The films were deposited using both screen-printing and a drop-coating method. It was found that the best response to pH was obtained from the screen-printed thick films, which demonstrated a change in conductance by as much as three orders of magnitude over the pH range pH2-pH11. The devices exhibited a stable response over 96 hours of operation. Several films were immersed in buffer solutions of different pH values for 96 hours and these were then investigated using XPS. The resulting N 1s spectra for the various films confirmed that the change in conductance was due to deprotonation of the PANI polymer backbone. SEM and Profilometry were also undertaken and showed that no considerable changes in the morphology of the films took place and that the films did not swell or contract due to exposure to test solutions.
引用
收藏
页码:3329 / 3346
页数:18
相关论文
共 42 条
[1]   Polymers in sensor applications [J].
Adhikari, B ;
Majumdar, S .
PROGRESS IN POLYMER SCIENCE, 2004, 29 (07) :699-766
[2]   Improved performance of polyaniline-uricase biosensor [J].
Arora, Kavita ;
Sumana, G. ;
Saxena, Vibha ;
Gupta, R. K. ;
Gupta, S. K. ;
Yakhmi, J. V. ;
Pandey, M. K. ;
Chand, Subhash ;
Malhotra, B. D. .
ANALYTICA CHIMICA ACTA, 2007, 594 (01) :17-23
[3]  
BREDAS JL, 1993, POLYANILINES ILLUSTR
[4]   Urea sensing film prepared by extrusion from DBSA-doped poly aniline-poly (styrene-co-potassium acrylate) in a poly(n-butyl methacrylate) matrix [J].
Castillo-Ortega, M. M. ;
Del Castillo-Castro, T. ;
Ibarra-Bracamontes, V. J. ;
Nuno-Donlucas, S. M. ;
Puig, J. E. ;
Herrera-Franco, P. J. .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 125 (02) :538-543
[5]  
Chandrasekhar P., 1999, CONDUCTING POLYM FUN
[6]   Optical sensing of pH based on polypyrrole films [J].
deMarcos, S ;
Wolfbeis, OS .
ANALYTICA CHIMICA ACTA, 1996, 334 (1-2) :149-153
[7]  
DHAND C, IN PRESS ANAL CHIM A
[8]   Detection of E-coli in water using semi-conducting polymeric thin film sensor [J].
Dixit, Vivechana ;
Tewari, Jagdish C. ;
Sharma, Bindu S. .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 120 (01) :96-103
[9]  
G_opel W., 1991, CHEM BIOCH SENSORS