Direct measurement of nitric oxide release from vascular endothelial cells

被引:70
作者
Guo, JP [1 ]
Murohara, T [1 ]
Buerke, M [1 ]
Scalia, R [1 ]
Lefer, AM [1 ]
机构
[1] THOMAS JEFFERSON UNIV, JEFFERSON MED COLL, DEPT PHYSIOL, PHILADELPHIA, PA 19107 USA
关键词
nitric oxide synthase; nitric oxide electrode;
D O I
10.1152/jappl.1996.81.2.774
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A nitric oxide (NO)-selective electrode was used to directly measure NO release from isolated rat aortic endothelium and cultured rat aortic endothelial cells (RAECs). Basal release of NO was significantly attenuated by a NO synthase inhibitor N-G-nitro-L-arginine methyl ester (1 mM) to 42 +/- 14 pmol/1 x 10(5) cells (P < 0.01). The basal release of NO was also significantly inhibited by a calmodulin antagonist W-7 at 15 mu M (P < 0.01). L-Arginine (1 mill), significantly stimulated NO release (P < 0.05 vs. control basal release). Stimulation of cultured RAECs with two endothelium-dependent vasodilators, acetylcholine (100 nM) and A-23187 (1 mu M), significantly increased NO release [574 +/- 112 pmol/l X 10(5) cells (n = 5) and 658 +/- 119 pmol/l x 10(5) cells (n = 5) in acetylcholine- and A-23187-stimulated RAECs, respectively]. Basal release of NO was also detectable in isolated rat aortic rings with intact endothelium. NO release was significantly attenuated by N-G-nitro-L-arginine methyl ester and augmented by human superoxide dismutase. These data indicate the physiological usefulness of the amperometric measurement of NO employing a NO-specific electrode in biological systems.
引用
收藏
页码:774 / 779
页数:6
相关论文
共 32 条