Validity of uniaxial accelerometry during activities of daily living in children

被引:46
作者
Eisenmann, JC
Strath, SJ
Shadrick, D
Rigsby, P
Hirsch, N
Jacobson, L
机构
[1] Iowa State Univ, Dept Hlth & Human Performance, Ames, IA 50011 USA
[2] Univ Michigan, Ann Arbor, MI 48109 USA
[3] Univ Wyoming, Laramie, WY 82071 USA
关键词
motion sensors; energy expenditure; physical activity; validity;
D O I
10.1007/s00421-003-0983-3
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The purpose of this study was to examine the validity of treadmill-based equations of two commonly used uniaxial accelerometers to estimate energy expenditure (EE) during activities of daily living in children. Twelve subjects with mean (SD) age11.4 (0.4) years engaged in a choreographed routine consisting of three activities (sweeping, bowling, and basketball) of 4min duration while wearing a Manufacturing Technology, Inc. (MTI) accelerometer, Caltrac accelerometer, and a portable gas analyzer (Cosmed K4b(2)). The equations of Trost et al. and Sallis et al. were used to convert activity counts to estimations of EE for the MTI and Caltrac, respectively. Correlation coefficients between Caltrac predictions of EE and measured EE from indirect calorimetry ranged from r=0.22 to 0.72 for individual activities. Correlations between MTI EE predictions and indirect calorimetry ranged from r=0.50 to 0.68 for individual activities. When the activities were pooled the correlations between EE from uniaxial accelerometers and EE from indirect calorimetry were moderately strong (MTI, r=0.78 and Caltrac, r=0.82). Inter-accelerometer (counts min(-1)) correlations were 0.08, -0.54, 0.63, and 0.79 for sweeping, bowling, basketball, and pooled data, respectively. The overall mean difference, or bias, and 95% confidence intervals (CI) for each uniaxial accelerometer compared to indirect calorimetry were as follows: Caltrac, bias = 2.80 (2.36, 3.24) kcal min(-1); MTI, bias = 0.88 (0.23, 1.53) kcal min(-1). Both accelerometers significantly underestimated measured EE (P<0.05). Uniaxial accelerometers provide potential for the measurement of physical activity (PA) and EE in children. Future studies refining accelerometry predictions of PA and EE are warranted.
引用
收藏
页码:259 / 263
页数:5
相关论文
共 27 条
[1]  
[Anonymous], 1996, Physical activity and health: A report of the Surgeon General
[2]  
[Anonymous], PEDIAT EXERCISE SCI
[3]  
[Anonymous], PEDIAT EXERCISE SCI
[4]  
Bailey D A, 1996, Exerc Sport Sci Rev, V24, P233
[5]   Validity of four motion sensors in measuring moderate intensity physical activity [J].
Bassett, DR ;
Ainsworth, BE ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
King, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S471-S480
[6]   Association between multiple cardiovascular risk factors and atherosclerosis in children and young adults [J].
Berenson, GS ;
Srinivasan, SR ;
Bao, WH ;
Newman, WP ;
Tracy, RE ;
Wattigney, WA .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (23) :1650-1656
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]  
Caspersen CJ, 1998, EXERCISE SPORT SCI R, V26, P341
[9]  
Eisenmann JC, 2003, J SPORT MED PHYS FIT, V43, P150
[10]  
Ekelund U, 2001, MED SCI SPORT EXER, V33, P275