Orthopedic implant cobalt-alloy particles produce greater toxicity and inflammatory cytokines than titanium alloy and zirconium alloy-based particles in vitro, in human osteoblasts, fibroblasts, and macrophages

被引:116
作者
Dalal, Ali [2 ]
Pawar, Vivek [3 ]
McAllister, Kyron [1 ]
Weaver, Carolyn [3 ]
Hallab, Nadim J. [1 ]
机构
[1] Rush Univ, Med Ctr, Dept Orthoped Surg, Chicago, IL 60612 USA
[2] Univ Illinois, Dept Orthoped Surg, Chicago, IL USA
[3] Smith & Nephew Inc, Memphis, TN USA
关键词
toxicity; metals; debris; inflammation; cytokines; ON-METAL BEARINGS; POLYCARBONATE-URETHANE PARTICLES; WEIGHT POLYETHYLENE PARTICLES; RELEVANT UHMWPE PARTICLES; LUMBAR DISC PROSTHESIS; TOTAL HIP-ARTHROPLASTY; WEAR PARTICLES; TNF-ALPHA; PERIPROSTHETIC TISSUES; NALP3; INFLAMMASOME;
D O I
10.1002/jbm.a.34122
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
The performance of total joint arthroplasty (TJA) depends on the size/shape, material, and amounts of implant debris. Much remains unknown in terms of which types of debris are most reactive. We compared the responses of human periimplant cells, osteoblasts, fibroblasts, and macrophages, exposed to particles of different metal-based particles (i.e., cobalt-chromium-molybdenum (CoCrMo) alloy, titanium (Ti) alloy, zirconium (Zr) oxide, and Zr alloy. CoCrMo-alloy particles were by far the most toxic (p < 0.05) and decreased viability and proliferation of human osteoblasts, fibroblasts, and macrophages by >50% at a dose of only 50 particles per cell. All particle types induced the production of interleukin (IL)-6, tumor necrosis factor (TNF)-a, and IL-8 by osteoblasts, fibroblasts, and monocytes/macrophages. However, the greatest cytokine responses of macrophages were to CoCrMo alloy (TNF-a and IL-8) and Ti alloy (IL-1 beta). Likewise, the greatest responses of fibroblasts and osteoblasts were to CoCrMo alloy (IL-6 and TNF-a) (i.e., IL-6 300 pg/mL; 30-fold max, TNF-a 150 pg/mL; 15-fold max) versus controls. For macrophages, CoCrMo particles induced IL-8 (> 2000 pg/mL; approx 100-fold max) above controls and were also significantly elevated above levels produced by Zr-based particles. Submicron sized (0.2-0.9 mu m) Zr-based particles (originally presumed to be more reactive) induced less toxicity and inflammatory responses when compared with larger (approx 1 mu m) CoCrMo-alloy and Ti-alloy particles. (C) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2012.
引用
收藏
页码:2147 / 2158
页数:12
相关论文
共 89 条
[1]
Anderson PA, SPINE IN PRESS
[2]
Cobalt ions influence proliferation and function of human osteoblast-like cells [J].
Anissian, L ;
Stark, A ;
Dahlstrand, H ;
Granberg, B ;
Good, V ;
Bucht, E .
ACTA ORTHOPAEDICA SCANDINAVICA, 2002, 73 (03) :369-374
[3]
Immunologic Adverse Reaction Associated with Low-carbide Metal-on-metal Bearings in Total Hip Arthroplasty [J].
Aroukatos, Panagiotis ;
Repanti, Maria ;
Repantis, Thomas ;
Bravou, Vassiliki ;
Korovessis, Panagiotis .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (08) :2135-2142
[4]
Synergistic effects of mixed TiAlV and polyethylene wear particles on TNFα response in THP-1 macrophages [J].
Baumann, Bernd ;
Rolf, Olaf ;
Jakob, Franz ;
Goebel, Sascha ;
Sterner, Thomas ;
Eulert, Jochen ;
Rader, Christof P. .
BIOMEDIZINISCHE TECHNIK, 2006, 51 (5-6) :360-366
[5]
Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses [J].
Brown, C ;
Fisher, J ;
Ingham, E .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) :355-369
[6]
An In Vitro Assessment of Wear Particulate Generated From NUBAC: A PEEK-on-PEEK Articulating Nucleus Replacement Device [J].
Brown, Tim ;
Bao, Qi-Bin ;
Agrawal, C. Mauli ;
Hallab, Nadim James .
SPINE, 2011, 36 (26) :E1675-E1685
[7]
Caicedo M, 2007, T 53 ORTH RES SOC, V53, P203
[8]
Soluble ions more than particulate cobalt-alloy implant debris induce monocyte costimulatory molecule expression and release of proinflammatory cytokines critical to metal-induced lymphocyte reactivity [J].
Caicedo, Marco S. ;
Pennekamp, Peter H. ;
McAllister, Kyron ;
Jacobs, Joshua J. ;
Hallab, Nadim J. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2010, 93A (04) :1312-1321
[9]
Soluble and Particulate Co-Cr-Mo Alloy Implant Metals Activate the Inflammasome Danger Signaling Pathway in Human Macrophages: A Novel Mechanism for Implant Debris Reactivity [J].
Caicedo, Marco S. ;
Desai, Ronak ;
McAllister, Kyron ;
Reddy, Anand ;
Jacobs, Joshua J. ;
Hallab, Nadim J. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (07) :847-854
[10]
ISOLATION OF PREDOMINANTLY SUBMICRON-SIZED UHMWPE WEAR PARTICLES FROM PERIPROSTHETIC TISSUES [J].
CAMPBELL, P ;
MA, S ;
YEOM, B ;
MCKELLOP, H ;
SCHMALZRIED, TP ;
AMSTUTZ, HC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (01) :127-131