The ventilation rate of 344 Oslo residences

被引:40
作者
Oie, L [1 ]
Stymne, H
Boman, CA
Hellstrand, V
机构
[1] Natl Inst Publ Hlth, Dept Populat Hlth Sci, Epidemiol Sect, Oslo, Norway
[2] Royal Inst Technol, Dept Built Environm, Gavle, Sweden
[3] PENTIAQ AB, Gavle, Sweden
来源
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE | 1998年 / 8卷 / 03期
关键词
indoor climate; ventilation; air change rate; passive tracer gas technique; perfluorocarbon; residences;
D O I
10.1111/j.1600-0668.1998.t01-1-00006.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The ventilation in Norwegian residences was studied with respect to the effect of new standards, construction techniques adopted, and energy conservation measures implemented. This was compared to residential ventilation performance in other countries with a similar climate. The effective total air change rate (h(-1)) in 344 residences was measured with a passive tracer gas method known as the perfluorocarbon tracer gas method (PFT-method). The measurements were performed over a 14-day integrated sampling period. Overall, 36% of all residences had lower air change rates than the national building code requirement of 0.5 h(-1). In spite of similar construction techniques and building codes in the Nordic countries, Norwegian residences seem to be better ventilated in general than residences in other Nordic countries. However, the common belief of a gradual reduction of ventilation rates in Norwegian buildings as the date of construction becomes more recent is supported by our findings which show a linear reduction (slope beta=-0.002, P<0.05) of ventilation until the revision of the national building codes in 1987. Consequently, our results provide evidence supporting the hypothesis that the introduction of new building standards and construction techniques, and the implementation of energy conservation measures, have decreased the effective total air change rates in Norwegian residences until 1987.
引用
收藏
页码:190 / 196
页数:7
相关论文
共 16 条
[1]  
Bergsoe NC, 1991, 213 SBI NAT I BUILD
[2]  
Brundrett G.W., 1977, ENERGY RES, V1, P289
[3]  
DALE HCA, 1985, ENERGY RES, V9, P431
[4]  
Dubrul C., 1988, 23 AIVC
[5]  
*IEA, 1991, ANN 14 COND EN, V1
[6]   CHANGES IN INDOOR CLIMATE AFTER TIGHTENING OF APARTMENTS [J].
KORSGAARD, J .
ENVIRONMENT INTERNATIONAL, 1983, 9 (02) :97-101
[7]  
LUNDQVIST GR, 1985, P 6 AIVC C BERKSH UK
[8]  
LUNDQVIST GR, 1986, UGESKRIFT LAEGER, V148, P3474
[9]   Breastfeeding, maternal smoking and lower respiratory tract infections [J].
Nafstad, P ;
Jaakkola, JJK ;
Hagen, JA ;
Botten, G ;
Kongerud, J .
EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (12) :2623-2629
[10]   Residential dampness problems and symptoms and signs of bronchial obstruction in young Norwegian children [J].
Nafstad, P ;
Oie, L ;
Mehl, R ;
Gaarder, PI ;
Lodrup-Carlsen, KC ;
Botten, G ;
Magnus, P ;
Jaakkola, JJK .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (02) :410-414