Factor analysis of hyphenated chromatographic data - Exploration, resolution and quantification of multicomponent systems

被引:74
作者
de Juan, Anna
Tauler, Roma
机构
[1] Univ Barcelona, Dept Analyt Chem, Chemometr Grp, E-08028 Barcelona, Spain
[2] CSIC, IIQAB, Barcelona, Spain
关键词
factor analysis; curve resolution; two-way data; three-way data;
D O I
10.1016/j.chroma.2007.05.045
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Factor analysis (FA) is a family of widely used methods to obtain the underlying sources of variation of data tables. Typically, hyphenated chromatographic data provide data tables with one elution direction and another linked to the detector response. In this context, the factors are the eluting compounds and the profiles defining each factor are the elution profile and the pure response of the compound. This article describes the use of FA in chromatography through diverse tools and problems. Examples of determination of number of compounds, peak purity problems, resolution of overlapped compounds or extension to simultaneous analysis of multiple runs (higher-order data structures) to obtain qualitative and quantitative information are reviewed. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 195
页数:12
相关论文
共 124 条
[1]  
[Anonymous], 1990, Journal ofChemometrics, DOI DOI 10.1002/CEM.1180040105
[2]  
[Anonymous], 2000, MULTIVARIATE DATA AN
[3]   Multivariate resolution of coeluted peaks in hyphenated liquid chromatography -: Linear sweep voltammetry [J].
Berbel, F ;
Kapoya, E ;
Díaz-Cruz, JM ;
Ariño, C ;
Esteban, M ;
Tauler, R .
ELECTROANALYSIS, 2003, 15 (5-6) :499-508
[4]   Analysis of three- and four-way data using multivariate curve resolution-alternating least squares with global multi-way kinetic fitting [J].
Bezemer, E ;
Rutan, SC .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2006, 81 (01) :82-93
[5]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[6]  
Bro R, 1999, J CHEMOMETR, V13, P295, DOI 10.1002/(SICI)1099-128X(199905/08)13:3/4<295::AID-CEM547>3.0.CO
[7]  
2-Y
[8]   A modification to window target-testing factor analysis using a Gaussian window [J].
Brown, CD ;
Wentzell, PD .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 51 (01) :3-7
[9]   Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography-mass spectrometry data [J].
Bylund, D ;
Danielsson, R ;
Malmquist, G ;
Markides, KE .
JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (02) :237-244
[10]   Recursive evolving spectral projection for revealing the concentration windows of overlapping peaks in two-way chromatographic experiments [J].
Chen, ZP ;
Morris, J ;
Martin, E ;
Yu, RQ ;
Liang, YZ ;
Gong, F .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2004, 72 (01) :9-19