Supercritical fluid simulated moving bed chromatography II. Langmuir isotherm

被引:29
作者
Di Giovanni, O
Mazzotti, M
Morbidelli, M
Denet, F
Hauck, W
Nicoud, RM
机构
[1] Swiss Fed Inst Technol, Tech Chem Lab, CH-8092 Zurich, Switzerland
[2] Swiss Fed Inst Technol, Inst Verfahrenstech, CH-8092 Zurich, Switzerland
[3] NOVASEP, F-54502 Vandoeuvre Les Nancy, France
关键词
simulated moving bed chromatography; supercritical fluid chromatography; Langmuir isotherm; adsorption isotherms;
D O I
10.1016/S0021-9673(01)00799-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The simulated moving bed (SMB) technology offers the possibility of scaling up single column, batch chromatographic separations to continuous operation. This has proved particularly effective for the separation of enantiomers, and has been applied in the liquid and gas phase, as well as using a supercritical fluid as eluent (SF-SMB). In the last case, the main performance improvements are due to the possibility of tuning the elution strength of the mobile phase, by changing the pressure in the four sections of the SMB unit. Thus a SF-SMB can be operated in two modes, i.e. the isocratic and the pressure gradient mode. In this research, design criteria for these two operating modes have been developed, which can be applied to systems described by linear as well as nonlinear Langmuir adsorption isotherms. The role and effect of an appropriate modifier in increasing solubility and reducing retention times have been investigated. The results reported allow to identify the operating conditions, including the pressure levels and the modifier concentration, which lead to optimal separation performance in terms of productivity and desorbent requirement. (C) 2001 Elsevier Science BN. All rights reserved.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 14 条
[1]  
[Anonymous], PHARM TECH EUR
[2]   Design and optimisation of a simulated moving bed unit: role of deviations from equilibrium theory [J].
Biressi, G ;
Ludemann-Hombourger, O ;
Mazzotti, M ;
Nicoud, RM ;
Morbidelli, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 876 (1-2) :3-15
[3]  
Clavier J. Y., 1996, HIGH PRESSURE CHEM E
[4]   Simulated moving-bed chromatography and its application to chirotechnology [J].
Juza, M ;
Mazzotti, M ;
Morbidelli, M .
TRENDS IN BIOTECHNOLOGY, 2000, 18 (03) :108-118
[5]   Continuous enantiomer separation of the Volatile inhalation anesthetic enflurane with a gas chromatographic simulated moving bed unit [J].
Juza, M ;
Di Giovanni, O ;
Biressi, G ;
Schurig, V ;
Mazzotti, M ;
Morbidelli, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 813 (02) :333-347
[6]   ADSORPTION-ISOTHERMS ON SILICA FOR METHANOL AND 1-HEXANOL MODIFIERS FROM SUPERCRITICAL CARBON-DIOXIDE [J].
LOCHMULLER, CH ;
MINK, LP .
JOURNAL OF CHROMATOGRAPHY, 1989, 471 :357-366
[7]   Supercritical fluid simulated moving bed chromatography [J].
Mazzotti, M ;
Storti, G ;
Morbidelli, M .
JOURNAL OF CHROMATOGRAPHY A, 1997, 786 (02) :309-320
[8]   Design of simulated moving bed units under nonideal conditions [J].
Migliorini, C ;
Gentilini, A ;
Mazzotti, M ;
Morbidelli, M .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (06) :2400-2410
[9]  
MIGLIORINI C, 2001, IN PRESS IND ENG CHE
[10]  
Nicoud R. M., 1999, PHARM TECHNOL EUR, V11, P36