A Comparative Biomechanical Evaluation of Hernia Mesh Fixation by Fibrin Sealant

被引:16
作者
Fortelny, Rene H. [2 ]
Petter-Puchner, Alexander H. [1 ]
Ferguson, James [1 ]
Gruber-Blum, Simone [1 ]
Brand, Julian [1 ]
Mika, Kathrin [1 ]
Redl, Heinz [1 ]
机构
[1] Ludwig Boltzmann Inst Expt & Clin Traumatol, Res Ctr AUVA, A-1200 Vienna, Austria
[2] Wilhelminenspital Stadt Wien, Dept Surg, Vienna, Austria
关键词
fibrin sealant; hernia mesh fixation; thrombin concentration; IPOM; TAPP; experimental model; biomechanics; REPAIR; GLUE; HERNIOPLASTY; TRIAL;
D O I
10.1016/j.jss.2010.06.001
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. The atraumatic fixation of meshes by fibrin sealant (FS) has been established for both open and laparoscopic techniques of hernia repair. This study was performed to evaluate the use of FS in hernia mesh fixation with different polymerization speed (thrombin concentrations), using commercial hernia meshes, and in two techniques, transabdominal preperitoneal mesh placement (TAPP) and intraperitoneal mesh placement (IPOM). Materials and Methods. A median laparotomy was performed in a pig model and hernia meshes were placed in IPOM and TAPP techniques. After mesh fixation with FS using thrombin concentrations of 4 and 500 IU/mL, maximum shear force before failure was measured at 5, 60, and 120 min. Results. At both thrombin concentrations and in all meshes in which the technique was used, the TAPP method tended to show higher maximum force levels at failure than did the IPOM method. In both TAPP and IPOM techniques and in all meshes, the 4 IU/mL thrombin concentration FS was superior to the 500 IU/mL thrombin concentration sealant. Conclusions. Although both thrombin concentrations are suitable for mesh fixation, lower concentrations allow slower polymerization and better sealant diffusion leading to higher maximum force levels at failure. The TAPP method was biomechanically superior to the IPOM method. There were no major differences between mesh products. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:576 / 581
页数:6
相关论文
共 17 条
[1]  
ALSTON SM, 2005, AUTOLOGOUS FIBRINOGE
[2]   Laparoscopic intraperitoneal mesh fixation with fibrin sealant (Tisseel®) vs. titanium tacks: a randomised controlled experimental study in pigs [J].
Eriksen, J. R. ;
Bech, J. I. ;
Linnemann, D. ;
Rosenberg, J. .
HERNIA, 2008, 12 (05) :483-491
[3]   Choice of mesh for laparoscopic ventral hernia repair [J].
Eriksen J.R. ;
Gögenur I. ;
Rosenberg J. .
Hernia, 2007, 11 (6) :481-492
[4]   The assessment of quality of life in a trial on lightweight mesh fixation with fibrin sealant in transabdominal preperitoneal hernia repair [J].
Fortelny, R. H. ;
Schwab, R. ;
Glaser, K. S. ;
Puchner, K. U. ;
May, C. ;
Koenig, F. ;
Redl, H. ;
Petter-Puchner, A. H. .
HERNIA, 2008, 12 (05) :499-505
[5]  
FORTELNY RH, EUROPEAN SU IN PRESS
[6]  
HELGERSON S, 2004, FIBRIN ENCY BIOMATER
[7]   Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair [J].
Katkhouda, N ;
Mavor, E ;
Friedlander, MH ;
Mason, RJ ;
Kiyabu, M ;
Grant, SW ;
Achanta, K ;
Kirkman, EL ;
Narayanan, K ;
Essani, R .
ANNALS OF SURGERY, 2001, 233 (01) :18-25
[8]   Tack entrapment of the ilioinguinal nerve during laparoscopic hernia repair [J].
Lantis, JC ;
Schwaitzberg, SD .
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES-PART A, 1999, 9 (03) :285-289
[9]   Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty - A randomized prospective trial [J].
Lau, H .
ANNALS OF SURGERY, 2005, 242 (05) :670-675
[10]   Use of human fibrin glue (Tissucol) versus staples for mesh fixation in laparoscopic transabdominal preperitoneal hernioplasty - A prospective, randomized study [J].
Lovisetto, Federico ;
Zonta, Sandro ;
Rota, Emanuela ;
Mazzilli, Massimiliano ;
Bardone, Marco ;
Bottero, Luca ;
Faillace, Giuseppe ;
Longoni, Mauro .
ANNALS OF SURGERY, 2007, 245 (02) :222-231