Exploiting the complementary nature of LC/MALDI/MS/MS and LC/ESI/MS/MS for increased proteome coverage

被引:144
作者
Bodnar, WM [1 ]
Blackburn, RK [1 ]
Krise, JM [1 ]
Moseley, MA [1 ]
机构
[1] GlaxoSmithKline, Genet Res Div, Proteom Technol, Res Triangle Pk, NC 27709 USA
关键词
D O I
10.1016/S1044-0305(03)00209-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The goal of this work was to evaluate the improvement in proteome coverage of complex protein mixtures gained by analyzing samples using both LC/ESI/MS/MS and LC/MALDI/ MS/MS. Parallel analyses of a single sample were accomplished by interfacing a Probot fractionation system with a nanoscale LC system. The Probot was configured to perform a post-column split such that a fraction (20%) of the column effluent was sent for on-line LC/ESI/MS/MS data acquisition, and the majority of the sample (80%) was mixed with a matrix solution and deposited onto the MALDI target plate. The split-flow approach takes advantage of the concentration sensitive nature of ESI and provides sufficient quantity of sample for MALDI/MS/MS. Hybrid quadrupole time-of-flight mass spectrometers were used to acquire LC/ESI/MS/MS data and LC/MALDI/MS/MS data from a tryptic digest of a preparation of mammalian mitochondrial ribosomes. The mass spectrometers were configured to operate in a data dependent acquisition mode in which precursor ions observed in MS survey scans are automatically selected for interrogation by MS/MS. This type of acquisition scheme maximizes the number of peptide fragmentation spectra obtained and is commonly referred to as shotgun analysis. While a significant degree of overlap (63%) was observed between the proteins identified in the LC/ESI/MS/MS and LC/MALDI/MS/MS data sets, both unique peptides and unique proteins were observed by each method. These results demonstrate that improved proteome coverage can be obtained using a combination of these ionization techniques.
引用
收藏
页码:971 / 979
页数:9
相关论文
共 25 条
  • [1] Bienvenut WV, 2002, PROTEOMICS, V2, P868, DOI 10.1002/1615-9861(200207)2:7<868::AID-PROT868>3.0.CO
  • [2] 2-D
  • [3] BURLINGAME AL, 2001, P 49 ASMS C MASS SPE
  • [4] Automated LC-LC-MS-MS platform using binary ion-exchange and gradient reversed-phase chromatography for improved proteomic analyses
    Davis, MT
    Beierle, J
    Bures, ET
    McGinley, MD
    Mort, J
    Robinson, JH
    Spahr, CS
    Yu, W
    Luethy, R
    Patterson, SD
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 752 (02): : 281 - 291
  • [5] Proteome analysis of low-abundance proteins using multidimensional chromatography and isotope-coded affinity tags
    Gygi, SP
    Rist, B
    Griffin, TJ
    Eng, J
    Aebersold, R
    [J]. JOURNAL OF PROTEOME RESEARCH, 2002, 1 (01) : 47 - 54
  • [6] JUHASZ P, 2002, P 50 ASMS C MASS SPE
  • [7] A proteomics approach to the identification of mammalian mitochondrial small subunit ribosomal proteins
    Koc, EC
    Burkhart, W
    Blackburn, K
    Moseley, A
    Koc, H
    Spremulli, LL
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 2000, 275 (42) : 32585 - 32591
  • [8] The large subunit of the mammalian mitochondrial ribosome - Analysis of the complement of ribosomal proteins present
    Koc, EC
    Burkhart, W
    Blackburn, K
    Moyer, MB
    Schlatzer, DM
    Moseley, A
    Spremulli, LL
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 2001, 276 (47) : 43958 - 43969
  • [9] Rapidly switchable matrix-assisted laser desorption/ionization and electrospray quadrupole-time-of-flight mass spectrometry for protein identification
    Krutchinsky, AN
    Zhang, WZ
    Chait, BT
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (06) : 493 - 504
  • [10] Direct analysis and identification of proteins in mixtures by LC/MS/MS and database searching at the low-femtomole level
    McCormack, AL
    Schieltz, DM
    Goode, B
    Yang, S
    Barnes, G
    Drubin, D
    Yates, JR
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (04) : 767 - 776