Directional dependence in film dosimetry: radiographic and radiochromic film

被引:74
作者
Suchowerska, N
Hoban, P
Butson, M
Davison, A
Metcalfe, P
机构
[1] Univ Sydney, Sch Med Radiat Sci, Lidcombe, NSW 1825, Australia
[2] Prince Wales Hosp, Dept Radiat Oncol, Randwick, NSW 2031, Australia
[3] Illawarra Canc Care Ctr, Dept Med Phys, Wollongong, NSW 2500, Australia
关键词
D O I
10.1088/0031-9155/46/5/305
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The trend towards conformal, intensity modulated radiotherapy treatments has established the need for a true integrating dosimeter. In traditional radiotherapy, radiographic film dosimetry is commonly used. The accuracy and reproducibility of film optical density as an indicator of dose is influenced by several variables, including the chemical processing conditions. As a result radiochromic film, with all the advantages of radiographic film but without the need for chemical processing, has increased in popularity, although the low-dose sensitivity of radiochromic film does remain a disadvantage for some experiments. Several studies have investigated the reproducibility of radiochromic film results, but none have specifically addressed the well-known directional dependence seen with traditional radiographic film. In this study, the directional dependence of radiographic (Kodak X-omat V) and radiochromic (Gafchromic (TM)) films were measured. It was found that both films over responded when exposed parallel to the central axis of the beam as opposed to perpendicular exposure. An attempt is made to explain the reason for the responses of both films in terms of spectral effects and the air gap between the phantom segments. Although radiographic film exposed parallel rather than perpendicular to the central axis of the beam exhibits a measured difference in film response at depth, this over response does not occur when the extent of the film is restricted to a small region at the centre of the phantom (this case an air gap is not introduced across the phantom). This suggests that it is the air gap rather than the orientation of the film that is the cause of the over response. Furthermore, when film occupies a slice through the entire phantom an over response occurs for both radiographic and radiochromic film, indicating that spectral effects are not the cause.
引用
收藏
页码:1391 / 1397
页数:7
相关论文
共 19 条
[1]   A new approach to film dosimetry for high energy photon beams: Lateral scatter filtering [J].
Burch, SE ;
Kearfott, KJ ;
Trueblood, JH ;
Sheils, WC ;
Yeo, JI ;
Wang, CKC .
MEDICAL PHYSICS, 1997, 24 (05) :775-783
[2]  
Carolan M. G., 1997, Australasian Physical and Engineering Sciences in Medicine, V20, P183
[3]  
CHU RDH, 1990, RADIAT PHYS CHEM, V35, P767
[4]  
Dutreix J, 1969, Ann N Y Acad Sci, V161, P33
[5]  
Hubbell J.H., 1995, 5632 NISTIR US DEP C
[6]  
KHAN FM, 1994, PHYSICS RAD THERAPY
[7]   DYNAMIC WEDGE FIELD TECHNIQUES THROUGH COMPUTER-CONTROLLED COLLIMATOR MOTION AND DOSE DELIVERY [J].
LEAVITT, DD ;
MARTIN, M ;
MOELLER, JH ;
LEE, WL .
MEDICAL PHYSICS, 1990, 17 (01) :87-91
[8]   TOMOTHERAPY - A NEW CONCEPT FOR THE DELIVERY OF DYNAMIC CONFORMAL RADIOTHERAPY [J].
MACKIE, TR ;
HOLMES, T ;
SWERDLOFF, S ;
RECKWERDT, P ;
DEASY, JO ;
YANG, J ;
PALIWAL, B ;
KINSELLA, T .
MEDICAL PHYSICS, 1993, 20 (06) :1709-1719
[9]   THE USE OF A RADIOCHROMIC DETECTOR FOR THE DETERMINATION OF STEREOTAXIC RADIOSURGERY DOSE CHARACTERISTICS [J].
MCLAUGHLIN, WL ;
SOARES, CG ;
SAYEG, JA ;
MCCULLOUGH, EC ;
KLINE, RW ;
WU, A ;
MAITZ, AH .
MEDICAL PHYSICS, 1994, 21 (03) :379-388
[10]   SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS [J].
MCLAUGHLIN, WL ;
YUNDONG, C ;
SOARES, CG ;
MILLER, A ;
VANDYK, G ;
LEWIS, DF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) :165-176