The quantification of renal function with enhanced computed tomography

被引:36
作者
Blomley, MJK [1 ]
Dawson, P [1 ]
机构
[1] HAMMERSMITH HOSP,LONDON W12 0HS,ENGLAND
关键词
D O I
10.1259/0007-1285-69-827-989
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The changes with time in renal parenchymal and vascular attenuation following injection of an intravascular contrast medium can be exploited to study renal physiology in several ways. Shortly after injection, both contrast medium clearance and fractional vascular volume per unit volume of kidney can be measured on a regional basis by obtaining sequential CT data from one anatomical level and the application of a graphical analysis to the baseline subtracted CT numbers for tissue and vascular regions of interest: c(t) and b(t), respectively. By plotting the ratio c(t)/b(t) against integral b(t)dt/b(t), both fractional vascular volume and contrast medium clearance can be estimated graphically. At later time points, a semilogarithmic plot against time of the declining attenuation of vascular or parenchymal regions of interest gives information about overall, as opposed to regional, renal function: the gradient estimates the glomerular filtration rate per unit volume of extracellular fluid. Absolute glomerular filtration rates can also be calculated with blood sampling. Although further experimental evaluation is needed, these techniques have a strong theoretical basis, and experimental work performed so far is encouraging. Possible applications of these techniques are discussed.
引用
收藏
页码:989 / 995
页数:7
相关论文
共 39 条
[1]   CONTRAST-MEDIA AS MARKERS FOR GLOMERULAR-FILTRATION - A PHARMACOKINETIC COMPARISON OF 4 AGENTS [J].
BACK, SE ;
KRUTZEN, E ;
NILSSONEHLE, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1988, 48 (03) :247-253
[2]   CONTRAST BOLUS DYNAMIC COMPUTED-TOMOGRAPHY FOR THE MEASUREMENT OF SOLID-ORGAN PERFUSION [J].
BLOMLEY, MJK ;
COULDEN, R ;
BUFKIN, C ;
LIPTON, MJ ;
DAWSON, P .
INVESTIGATIVE RADIOLOGY, 1993, 28 :S72-S77
[3]   RENAL PERFUSION QUANTIFIED WITH CONTRAST-ENHANCED COMPUTED-TOMOGRAPHY [J].
BLOMLEY, MJK ;
KORMANO, M ;
COULDEN, R ;
STARK, V ;
BUFKIN, C ;
LIPTON, MJ .
INVESTIGATIVE RADIOLOGY, 1994, 29 :S232-S233
[4]  
BLOMLEY MJK, 1996, IN PRESS ACAD RADIOL
[5]  
BLOMLEY MJK, 1993, BR J RADIOL C S, V66, P25
[6]  
BOIJSEN M, 1987, ACTA RADIOL, V28, P581
[7]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[8]   COMPARISON OF DIATRIZOATE, IOPAMIDOL, AND IOXAGLATE FOR THE CONTRAST ENHANCEMENT OF EXPERIMENTAL HEPATIC-TUMORS IN CT [J].
BURGENER, FA ;
STEINMETZ, SD .
INVESTIGATIVE RADIOLOGY, 1985, 20 (06) :626-631
[9]   1ST-PASS ENTRY OF NONIONIC CONTRAST AGENT INTO THE MYOCARDIAL EXTRAVASCULAR SPACE - EFFECTS ON RADIOGRAPHIC ESTIMATES OF TRANSIT-TIME AND BLOOD-VOLUME [J].
CANTY, JM ;
JUDD, RM ;
BRODY, AS ;
KLOCKE, FJ .
CIRCULATION, 1991, 84 (05) :2071-2078
[10]   HEPATIC CT ENHANCEMENT - COMPARISON OF IONIC AND NONIONIC CONTRAST AGENTS IN THE SAME PATIENTS [J].
CHAMBERS, TP ;
BARON, RL ;
LUSH, RM ;
DODD, GD ;
MILLER, WJ .
RADIOLOGY, 1994, 190 (03) :721-725