Automated coupling of capillary-HPLC to matrix-assisted laser desorption ionization mass spectrometry for the analysis of small molecules utilizing a reactive matrix

被引:40
作者
Brombacher, S [1 ]
Owen, SJ [1 ]
Volmer, DA [1 ]
机构
[1] Natl Res Council Canada, Inst Marine Biosci, Halifax, NS B3H 3Z1, Canada
关键词
D O I
10.1007/s00216-003-2024-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study describes the application of a novel, reactive matrix for the mass spectral analysis of steroids by capillary-high performance liquid chromatography (capillary-HPLC) coupled to matrix-assisted laser desorption/ionization (MALDI). The mass spectral analysis of steroids was accomplished after fully automated peak deposition of chromatographic peaks onto MALDI targets. The seven corticosteroids used as test compounds were: triamcinolone, prednisone, cortisone, fludrocortisone, dexamethasone, deoxycorticosterone, and budesonide. They were separated using a PepMap C-18 (3 mum particle size, 100 Angstrom pore width) column at five different concentration levels of 25, 15, 7.5, 2.5 and 1 ng/muL, and the peaks were detected at a wavelength of 237 nm. The column effluent was mixed with 2,4-dinitrophenylhydrazine (DNPH) directly following the UV detector. The chromatographic peaks were then deposited onto the MALDI target with a robotic micro-fraction collector triggered by the UV detector signals. A special hydrophobic surface coating allowed the deposition of up to 4 muL (up to 90 % of the chromatographic peak volume) onto one sample spot. The compounds were then identified by MALDI mass spectrometry. Depending on the nature of the analyte, radical cations ([M](+.)) and sodium adduct ions ([M+Na](+)) of the steroids as well as protonated steroid-dinitrophenylhydrazone derivatives ([M-D+H](+)) were detected in positive ion mode. The detection limits were between 0.5 and 15 ng injected with capillary-HPLC-MALDI-TOF-MS and between 0.3 and 3 ng on target with MALDI-TOF when deposited manually.
引用
收藏
页码:773 / 779
页数:7
相关论文
共 35 条
[1]  
Allwood DA, 1996, RAPID COMMUN MASS SP, V10, P1575, DOI 10.1002/(SICI)1097-0231(199610)10:13<1575::AID-RCM658>3.0.CO
[2]  
2-C
[3]   Optical absorption of matrix compounds for laser-induced desorption and ionization (MALDI) [J].
Allwood, DA ;
Dreyfus, RW ;
Perera, IK ;
Dyer, PE .
APPLIED SURFACE SCIENCE, 1997, 109 :154-157
[4]   Accurate mass measurement of synthetic analogues of prazosine by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry [J].
Andalò, C ;
Bocchini, P ;
Pozzi, R ;
Galletti, GC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (09) :665-669
[5]  
Biot C, 1998, J LABELLED COMPD RAD, V41, P911, DOI 10.1002/(SICI)1099-1344(1998100)41:10<911::AID-JLCR145>3.0.CO
[6]  
2-4
[7]   HPLC combined with multiple mass spectrometry (MSn):: an alternative for the structure elucidation of compounds and artefacts found in smog chamber samples [J].
Brombacher, S ;
Oehme, M ;
Beukes, JA .
JOURNAL OF ENVIRONMENTAL MONITORING, 2001, 3 (03) :311-316
[8]  
Busch KL, 1999, SPECTROSCOPY, V14, P14
[9]   TRACE ENRICHMENT METHODS FOR THE DETERMINATION OF ORGANIC POLLUTANTS IN AMBIENT AIR [J].
CAMEL, V ;
CAUDE, M .
JOURNAL OF CHROMATOGRAPHY A, 1995, 710 (01) :3-19
[10]  
CAREY FA, 1990, ADV ORG CHEM, V3, P802