Impedancemetric gas sensor based on zirconia solid electrolyte and oxide sensing electrode for detecting total NOx at high temperature

被引:164
作者
Miura, N [1 ]
Nakatou, M [1 ]
Zhuiykov, S [1 ]
机构
[1] Kyushu Univ, Adv Sci & Technol Ctr COoperat Res, Kasuga, Fukuoka 8168580, Japan
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2003年 / 93卷 / 1-3期
关键词
NOx sensor; stabilized zirconia; complex impedance; oxide electrode; automobile exhaust; spinel-type oxide; ZnCr2O4;
D O I
10.1016/S0925-4005(03)00196-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A solid-state electrochemical NOx sensor was fabricated by using a closed-one-end yttria-stabilized zirconia (YSZ) tube, an oxide sensing electrode (SE) and a Pt counter electrode (CE). The complex impedance of the device using each of several oxide SEs was measured in the frequency and the temperature ranges of 0.1 Hz to 100 kHz and 600-700 degreesC, respectively. In most cases, a large semicircular arc was observed in complex impedance spectra (Nyquist plots) in the lower frequency range examined in dry-air flow. Only in the case of the device using ZnCr2O3 SE, the semi-arc shrank to some extent upon exposure to NOx gas. The resistance value (Z') at the intersection of the semi-arc with the real axis at lower frequencies (around 0.1 Hz) varied with concentration of both NO and NO2 in the sample gas. The impedance value at 1 Hz of the present device was found to vary almost linearly with the concentration of NO (or NOD from 50 to 400 ppm. The 90% response and 90% recovery times were as short as less than few seconds at 700 degreesC. Furthermore, it is noted that the sensitivity of NO is almost equal to that of NO2. This indicates that the present device can detect the total No, at higher temperatures. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:221 / 228
页数:8
相关论文
共 20 条
[1]  
HASEI M, 2000, SAE TECH PAPER SERIE
[2]   NOx response properties in DC current of Nd2CuO4/4YSZ/Pt element [J].
Ho, KY ;
Miyayama, M ;
Yanagida, H .
JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 1996, 104 (11) :995-999
[3]  
KATO N, 1998, SAE TECH PAPER SERIE
[4]  
KATO N, 1996, SAE TECH PAPER SERIE
[5]  
KUMIMOTO A, 1999, SAE TECH PAPER SERIE
[6]   High-Temperature NO or NO2 Sensor Using Stabilized Zirconia and Tungsten Oxide Electrode [J].
Lu, G. ;
Miura, N. ;
Yamazoe, N. .
IONICS, 1998, 4 (1-2) :16-24
[7]   Critical review of nitrogen monoxide sensors for exhaust gases of lean burn engines [J].
Ménil, F ;
Coillard, V ;
Lucat, C .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 67 (1-2) :1-23
[8]   Mixed potential type sensor using stabilized zirconia and ZnFe2O4 sensing electrode for NOx detection at high temperature [J].
Miura, N ;
Zhuiykov, S ;
Ono, T ;
Hasei, M ;
Yamazoe, N .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 83 (1-3) :222-229
[9]   Impedance-based total-NOx sensor using stabilized zirconia and ZnCr2O4 sensing electrode operating at high temperature [J].
Miura, N ;
Nakatou, M ;
Zhuiykov, S .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (04) :284-287
[10]   High-temperature potentiometric/amperometric NOx sensors combining stabilized zirconia with mixed-metal oxide electrode [J].
Miura, N ;
Lu, GY ;
Yamazoe, N .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 52 (1-2) :169-178