The effect of changing excitation frequency on parallel conductance in different sized hearts

被引:16
作者
White, PA
Brookes, CIO
Ravn, HB
Stenbog, EE
Christensen, TD
Chaturvedi, RR
Sorensen, K
Hjortdal, VE
Redington, AN
机构
[1] Royal Brompton & Natl Heart Hosp, Dept Paediat Cardiol, London SW3 6NP, England
[2] Royal Brompton & Natl Heart Hosp, Dept Adult Cardiol, London SW3 6NP, England
[3] Aarhus Univ Hosp, Inst Expt Clin Res, DK-8000 Aarhus, Denmark
[4] Aarhus Univ Hosp, Dept Cardiol, DK-8000 Aarhus, Denmark
关键词
pig; neonatal; adult; left ventricle; conductance catheter; saline wash-in; parallel conductance; dual frequency excitation;
D O I
10.1016/S0008-6363(98)00052-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: An important component of the ventricular volume measured using the conductance catheter technique is due to parallel conductance (Vc), which results from the extension of the electric field beyond the ventricular blood pool. parallel conductance volume is normally estimated using the saline dilution method (Vc(saline dilution)), in which the conductivity of blood in the ventricle is transiently increased by injection of hypertonic saline. A simpler alternative has been reported by Gawne et al, [12], Vc(dual frequency) is estimated from the difference in total conductance measured at two exciting frequencies and the method is based on the assumption that parallel conductance is mainly capacitive and hence is negligible at low frequency. The objective of this study was to determine whether the dual frequency technique could be used to substitute the saline dilution method to estimate Vc in different sized hearts. Methods: The accuracy and linearity of a custom-built conductance catheter (CC) system was initially assessed in vitro. Subsequently, a CC and micromanometer were inserted into the left ventricle of seven 5 kg pigs (group 1) and six 50 kg pigs (group 2). Cardiac output was determined using thermodilution (group 1) and an ultrasonic flow probe (group 2) from which the slope coefficient (alpha) was determined. Steady state measurements and Vc estimated using saline dilution were performed at frequencies in the range of 5-40 kHz. All measurements were made at end-expiration. Finally, Vc was estimated from the change in end-systolic conductance between 5 kHz and 40 kHz using the dual frequency technique of Gawne et al. [12]. Results: There was no change in measured volume of a simple insulated cylindrical model when the stimulating frequency was varied from 5-40 kHz, Vc(saline dilution) varied significantly with frequency in group 1 (8.63 +/- 2.74 ml at 5 kHz; 11.51 +/- 2.65 ml at 40 kHz) (p = 0.01). Similar results were obtained in group 2 (69.43 +/- 27.76 ml at 5 kHz; 101.24 +/- 15.21 ml at 40 kHz) (p < 0.001). However, the data indicate that the resistive component of the parallel conductance is substantial (Vc at 0 Hz estimated as 8.01 ml in group 1 and 62.3 ml in group 2). There was an increase in alpha with frequency in both groups but this did not reach significance. The correspondence between Vc(dual frequency) and Vc(saline dilution) methods was poor (group 1 R-2 = 0.69; group 2 R-2 = 0.22). Conclusion: At a lower excitation frequency of 5 kHz a smaller percentage of the electric current extends beyond the blood pool so parallel conductance is reduced. While parallel conductance is frequency dependent, it has a substantial resistive component. The dual frequency method is based on the assumption that parallel conductance is negligible at low frequencies and this is clearly not the case. The results of this study confirm that the dual frequency technique cannot be used to substitute the saline dilution technique. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:668 / 675
页数:8
相关论文
共 23 条
  • [1] [Anonymous], 1985, GUIDE CARE USE LAB A
  • [2] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER
    BAAN, J
    VANDERVELDE, ET
    DEBRUIN, HG
    SMEENK, GJ
    KOOPS, J
    VANDIJK, AD
    TEMMERMAN, D
    SENDEN, J
    BUIS, B
    [J]. CIRCULATION, 1984, 70 (05) : 812 - 823
  • [3] CONTINUOUS STROKE VOLUME AND CARDIAC-OUTPUT FROM INTRAVENTRICULAR DIMENSIONS OBTAINED WITH IMPEDANCE CATHETER
    BAAN, J
    JONG, TTA
    KERKHOF, PLM
    MOENE, RJ
    VANDIJK, AD
    VANDERVELDE, ET
    KOOPS, J
    [J]. CARDIOVASCULAR RESEARCH, 1981, 15 (06) : 328 - 334
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] ACCURACY OF VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN ISOLATED, EJECTING CANINE HEARTS
    BURKHOFF, D
    VANDERVELDE, E
    KASS, D
    BAAN, J
    MAUGHAN, WL
    SAGAWA, K
    [J]. CIRCULATION, 1985, 72 (02) : 440 - 447
  • [6] ASSESSMENT OF RIGHT-VENTRICULAR CONTRACTILE STATE WITH THE CONDUCTANCE CATHETER TECHNIQUE IN THE PIG
    DICKSTEIN, ML
    YANO, O
    SPOTNITZ, HM
    BURKHOFF, D
    [J]. CARDIOVASCULAR RESEARCH, 1995, 29 (06) : 820 - 826
  • [7] DUCK FA, 1990, PHYSICAL PROPERTIES, pCH6
  • [8] DETECTION OF LEFT-VENTRICULAR REGIONAL MYOCARDIAL ISCHEMIA IN DOGS BY INTRAVENTRICULAR CONDUCTANCE CATHETER
    FISCHER, EIC
    SPINELLI, JC
    WILLSHAW, P
    CROTTOGINI, AJ
    DEFORTEZA, E
    CLAVIN, O
    VALENTINUZZI, ME
    PICHEL, RH
    [J]. CARDIOVASCULAR RESEARCH, 1988, 22 (03) : 185 - 192
  • [9] ESTIMATING LEFT-VENTRICULAR OFFSET VOLUME USING DUAL-FREQUENCY CONDUCTANCE CATHETERS
    GAWNE, TJ
    GRAY, KS
    GOLDSTEIN, RE
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (02) : 872 - 876
  • [10] VOLUME CONDUNCTANCE CATHETER
    GLANTZ, SA
    BOLTWOOD, CM
    APPLEYARD, RF
    APPLEGATE, RJ
    CHENG, CP
    LITTLE, WC
    [J]. CIRCULATION, 1990, 81 (06) : 2028 - 2028