This paper presents an experimental technique to measure the directional thermal conductivity and thermal diffusivity of materials, A heated thermistor heats the sample and a sensing thermistor placed about 2.5 mm away measures the temperature rise due the heating pulse at the heated thermistor, An empirical relation between the power delivered by the first thermistor and the temperature rise recorded by the sensing thermistor is used to measure the thermal conductivity of the material along the line joining the thermistors. Diffusivity of the material is determined from the delay between the power pulse in the heated thermistor and the temperature pulse at the sensing thermistor. Signal processing was done to eliminate errors in the measurement due to change of base line temperature, Uncertainty of the measurement technique was found to be 5% when tested in media of known thermal properties. The thermal conductivity and thermal diffusivity of swine left ventricle in normal and ablated conditions were measured using this technique. The thermal conductivity of the tissue dropped significantly from 0.61 to 0.50 W . m(-1) . K-1 after ablation while the diffusivity dropped from 2.1 x 10(-7) to 1.7 x 10(-7) m(2) . s(-1).
引用
收藏
页码:261 / 267
页数:7
相关论文
共 19 条
[1]   SELF-HEATED THERMISTOR MEASUREMENTS OF PERFUSION [J].
ANDERSON, GT ;
VALVANO, JW ;
SANTOS, RR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (09) :877-885
[2]   THERMAL PULSE DECAY METHOD FOR SIMULTANEOUS MEASUREMENT OF LOCAL THERMAL-CONDUCTIVITY AND BLOOD PERFUSION - A THEORETICAL-ANALYSIS [J].
ARKIN, H ;
HOLMES, KR ;
CHEN, MM ;
BOTTJE, WG .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (03) :208-214
[3]  
BALASUBRAMANIAM TA, 1977, ASME J BIOMECHANICAL, V99, P148
[4]   Thermophysical properties of swine myocardium [J].
Bhavaraju, NC ;
Valvano, JW .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1999, 20 (02) :665-676
[5]  
Bowman H.F., 1985, HEAT TRANSFER MED BI, VI, P193
[6]  
CHATO JC, 1985, HEAT TRANSFER MED BI, P167
[7]  
Chato JC, 1968, P S THERM PROBL BIOT, P16
[8]   PULSE-DECAY METHOD FOR MEASURING THE THERMAL-CONDUCTIVITY OF LIVING TISSUES [J].
CHEN, MM ;
HOLMES, KR ;
RUPINSKAS, V .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1981, 103 (04) :253-260
[9]   EXPERIMENTAL-VERIFICATION OF BIOHEAT TRANSFER THEORIES - MEASUREMENT OF TEMPERATURE PROFILES AROUND LARGE ARTIFICIAL VESSELS IN PERFUSED TISSUE [J].
CREZEE, J ;
LAGENDIJK, JJW .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (07) :905-923
[10]   A finite element model of a microwave catheter for cardiac ablation [J].
Kaouk, Z ;
Khebir, A ;
Savard, P .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1996, 44 (10) :1848-1854