Coloured microsphere assessment of blood flow to knee ligaments in adult rabbits: Effects of injury

被引:24
作者
Bray, RC [1 ]
Butterwick, DJ [1 ]
Doschak, MR [1 ]
Tyberg, JV [1 ]
机构
[1] UNIV CALGARY, FAC MED, CARDIOVASC RES GRP, CALGARY, AB, CANADA
关键词
D O I
10.1002/jor.1100140417
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Coloured microspheres were used to determine standardized blood flow in an established model of medial collateral ligament injury in the adult rabbit knee. Resting blood flow in the ligament was ascertained to be on the order of 0.68 +/- 0.08 ml/min/100 g (mean +/- SEM) in normal rabbit knees, although errors in flow estimates of this magnitude may be quite high. In healing medial collateral ligament, however, flow had increased markedly 3 weeks after injury (21.45 +/- 5.48 ml/min/100 g). Flows in sham-operated control medial collateral ligaments were not significantly increased compared with those in control normal ligaments, Six weeks after injury, blood flow in the ligament remained elevated (16.90 +/- 3.20 ml/min/100 g) and was similarly elevated in other neighbouring joint tissues (i.e., ipsilateral synovial Eat pad). The increase in flow to ipsilateral noninjured articular tissues did not persist beyond 6 weeks, but flow in the healing medial collateral ligament scar tended to remain elevated after 17 weeks (4.20 +/- 1.79 ml/min/100 g), although this did not achieve statistical significance. We conclude from these data that it is possible to measure the increase in blood flow in injured and healing articular tissues using the coloured microspheres technique and that ligament injury is a potent stimulus for increasing blood flow. Coloured microsphere measurements of blood flow to joint connective tissues map offer a valuable approach to future investigations of joint injury and arthritis.
引用
收藏
页码:618 / 625
页数:8
相关论文
共 35 条
  • [1] ANGERSON WJ, 1990, J PHYSIOL-LONDON, V422, pP24
  • [2] MICROVASCULATURE OF THE CRUCIATE LIGAMENTS AND ITS RESPONSE TO INJURY - EXPERIMENTAL-STUDY IN DOGS
    ARNOCZKY, SP
    RUBIN, RM
    MARSHALL, JL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (08) : 1221 - 1229
  • [3] QUANTITATING ERROR IN BLOOD-FLOW MEASUREMENTS WITH RADIOACTIVE MICROSPHERES
    AUSTIN, RE
    HAUCK, WW
    ALDEA, GS
    FLYNN, AE
    COGGINS, DL
    HOFFMAN, JIE
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (01): : H280 - H288
  • [4] BRAY R, 1994, T ORTHOP RES SOC, V19, P790
  • [5] BRAY R, 1994, ORTHOP T, V17, P631
  • [6] BRAY RC, 1990, J ANAT, V172, P69
  • [7] SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES
    BUCKBERG, GD
    LUCK, JC
    PAYNE, DB
    HOFFMAN, JIE
    ARCHIE, JP
    FIXLER, DE
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) : 598 - &
  • [8] BUTTERWICK D, 1992, P CAN ORTHOP RES SOC, V26, P25
  • [9] *CAN COUNC AN CAR, 1993, GUID CAR US EXP AN, V2
  • [10] *CAN COUNC AN CAR, 1993, GUID CAR US EXP AN, V1