Exergoenvironmental analysis and optimization of a cogeneration plant system using Multimodal Genetic Algorithm (MGA)

被引:192
作者
Ahmadi, Pouria [1 ]
Dincer, Ibrahim [1 ]
机构
[1] UOIT, Fac Engn & Appl Sci, Dept Mech Engn, Oshawa, ON L1H 7K4, Canada
关键词
Exergoenvironmental optimization; CHP; Exergy; Energy; Efficiency; Genetic algorithm; EXERGETIC PERFORMANCE EVALUATION; EXERGOECONOMIC ANALYSIS; COMBINED HEAT; POWER-SYSTEM; ENERGY;
D O I
10.1016/j.energy.2010.07.050
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present work, a combined heat and power plant for cogeneration purposes that produces 50 MW of electricity and 33.3 kg/s of saturated steam at 13 bar is optimized using genetic algorithm. The design parameters of the plant considered are compressor pressure ratio (r(AC)), compressor isentropic efficiency (eta(comp)), gas turbine isentropic efficiency (eta(GT)), combustion chamber inlet temperature (T-3), and turbine inlet temperature (TIT). In addition, to optimally find the optimum design parameters, an exergoeconomic approach is employed. A new objective function, representing total cost rate of the system product including cost rate of each equipment (sum of the operating cost, related to the fuel consumption) and cost rate of environmental impact (NOx and CO) is considered. Finally, the optimal values of decision variables are obtained by minimizing the objective function using evolutionary genetic algorithm. Moreover, the influence of changes in the demanded power on various design parameters are parametrically studied for 50, 60, 70 MW of net power output. The results show that for a specific unit cost of fuel, the values of design parameters increase, as the required, with net power output increases. Also, the variations of the optimal decision variables versus unit cost of fuel reveal that by increasing the fuel cost, the pressure ratio, r(AC), compressor isentropic efficiency, eta(AC), turbine isentropic efficiency, eta(GT). and turbine inlet temperature (TIT) increase. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5161 / 5172
页数:12
相关论文
共 46 条
[1]  
AHMADI P, 2008, P 16 INT C MECH ENG, P2243
[2]  
AHMADI P, 2007, P 1 IR THERM C ISF I
[3]  
AHMADI P, 2008, P ASME SUMM HEAT TRA
[4]  
AHMADI P, 2006, THESIS POWER WATER U
[5]   Energy and exergy analysis of a steam power plant in Jordan [J].
Aijundi, Isam H. .
APPLIED THERMAL ENGINEERING, 2009, 29 (2-3) :324-328
[6]   Exergy analysis of a 420 MW combined cycle power plant [J].
Ameri, M. ;
Ahmadi, P. ;
Khanmohammadi, S. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (02) :175-183
[7]   The study of ambient temperature effects on exergy losses of a heat Recovery Steam Generator [J].
Ameri, Mohammad ;
Ahmadi, Pourya .
CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, :55-+
[8]   Thermodynamic analysis of a tri-generation system based on micro-gas turbine with a steam ejector refrigeration system [J].
Ameri, Mohammad ;
Behbahaninia, Ali ;
Tanha, Amir Abbas .
ENERGY, 2010, 35 (05) :2203-2209
[9]   Energy, exergy and exergoeconomic analysis of a steam power plant: A case study [J].
Ameri, Mohammad ;
Ahmadi, Pouria ;
Hamidi, Armita .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (05) :499-512
[10]  
[Anonymous], THESIS SHIRAZ U TECH