Computer-assisted robotic Heller myotomy: Initial case report
被引:49
作者:
Melvin, WS
论文数: 0引用数: 0
h-index: 0
机构:
Ohio State Univ, Med Ctr, Ctr Minimally Invas Surg, Div Gen Surg, Columbus, OH 43210 USAOhio State Univ, Med Ctr, Ctr Minimally Invas Surg, Div Gen Surg, Columbus, OH 43210 USA
Melvin, WS
[1
]
Needleman, BJ
论文数: 0引用数: 0
h-index: 0
机构:
Ohio State Univ, Med Ctr, Ctr Minimally Invas Surg, Div Gen Surg, Columbus, OH 43210 USAOhio State Univ, Med Ctr, Ctr Minimally Invas Surg, Div Gen Surg, Columbus, OH 43210 USA
Needleman, BJ
[1
]
Krause, KR
论文数: 0引用数: 0
h-index: 0
机构:
Ohio State Univ, Med Ctr, Ctr Minimally Invas Surg, Div Gen Surg, Columbus, OH 43210 USAOhio State Univ, Med Ctr, Ctr Minimally Invas Surg, Div Gen Surg, Columbus, OH 43210 USA
Krause, KR
[1
]
Wolf, RK
论文数: 0引用数: 0
h-index: 0
机构:
Ohio State Univ, Med Ctr, Ctr Minimally Invas Surg, Div Gen Surg, Columbus, OH 43210 USAOhio State Univ, Med Ctr, Ctr Minimally Invas Surg, Div Gen Surg, Columbus, OH 43210 USA
Wolf, RK
[1
]
Michler, RE
论文数: 0引用数: 0
h-index: 0
机构:
Ohio State Univ, Med Ctr, Ctr Minimally Invas Surg, Div Gen Surg, Columbus, OH 43210 USAOhio State Univ, Med Ctr, Ctr Minimally Invas Surg, Div Gen Surg, Columbus, OH 43210 USA
Michler, RE
[1
]
Ellison, EC
论文数: 0引用数: 0
h-index: 0
机构:
Ohio State Univ, Med Ctr, Ctr Minimally Invas Surg, Div Gen Surg, Columbus, OH 43210 USAOhio State Univ, Med Ctr, Ctr Minimally Invas Surg, Div Gen Surg, Columbus, OH 43210 USA
Ellison, EC
[1
]
机构:
[1] Ohio State Univ, Med Ctr, Ctr Minimally Invas Surg, Div Gen Surg, Columbus, OH 43210 USA
来源:
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES-PART A
|
2001年
/
11卷
/
04期
关键词:
D O I:
10.1089/109264201750539790
中图分类号:
R61 [外科手术学];
学科分类号:
摘要:
Purpose: Our objective was to determine the efficacy of computer-assisted robotic laparoscopic Heller myotomy. Methods: A 76-year-old woman with a significant history of achalasia was evaluated for laparoscopic Heller myotomy. The daVinci(TM) surgical system was used throughout the procedure. Results: Computer assistance allowed scaling of hand motions from a range of 2:1 to 5:1. Successful dissection of the esophageal musculature was accomplished, and a Toupet-type fundoplication was performed. The patient was discharged from the hospital the day after surgery with five port incisions, each < 1 cm. Conclusions: Telemanipulator computer-assisted surgical devices may have applications in procedures that require advanced and finely tuned motions, such as Heller myotomy. The benefits of extra magnification and three-dimensional imaging can help prevent esophageal perforation and identify residual circular muscle fibers.