In vitro measurements of flow using multislice computed tomography (MSCT)

被引:20
作者
Lackner, Klaus [1 ]
Bovenschulte, Henning [1 ]
Stuetzer, Hartmut [2 ]
Just, Thomas [1 ]
Al-Hassani, Hassan [1 ]
Krug, Barbara [1 ]
机构
[1] Univ Cologne, Sch Med, Dept Radiol, D-50924 Cologne, Germany
[2] Univ Cologne, Sch Med, Dept Med Stat Informat & Epidemiol, D-50924 Cologne, Germany
关键词
Blood flow; CT quantification of flow; Stenosis grade quantification; In vitro study; CORONARY-ARTERY-DISEASE; MYOCARDIAL-PERFUSION; DIAGNOSTIC PERFORMANCE; ANGIOGRAPHY; ACCURACY; STENOSIS; CT;
D O I
10.1007/s10554-010-9728-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To examine in vitro whether an assessment of flow in normal and obstructed vessels is essentially possible using modern multislice CT-scanners. An experimental model allowed known stenoses to be perfused at defined flow rates. Aorta and coronary arteries were simulated by silicone tubes. A pulsatile pump was used to perfuse water through the system with intermittent injection of a bolus of radio-opaque contrast agent. CT-measurements were carried out with slice orientation perpendicular to the tubes. 50-90% concentric stenoses were examined 5 times at 4 different stenosis slice distances. A mathematical algorithm calculated the temporal density changes within a ROI in the tube cross-sections. Quantitative assessment of the data simultaneously acquired with the 16-slice system for the "coronary" and "aortal" time-density curves showed that the model allowed for exclusion of a a parts per thousand yen 80% stenosis grade with a 99% probability when the slopes of the density increase quotient was > 0.79; a stenosis grade of a parts per thousand yen 90% could be excluded when the slopes of the density increase quotient was > 0.52. A Quotient > 0.94 for "peak density" was associated with a 99% probability of a stenosis grade a parts per thousand yen 70%. The 64-slice system allowed stenosis grades of a parts per thousand yen 80% to be discriminated from lower grades. The general feasibility of the in vitro approach was verified in an in vivo model. The spatial, contrast and temporal resolution of CT scanners with at least 16 detector rows enables qualitative and semiquantitative assessment of stenotic changes in flow.
引用
收藏
页码:795 / 804
页数:10
相关论文
共 15 条
[1]   TISSUE MEAN TRANSIT-TIME FROM DYNAMIC COMPUTED-TOMOGRAPHY BY A SIMPLE DECONVOLUTION TECHNIQUE [J].
AXEL, L .
INVESTIGATIVE RADIOLOGY, 1983, 18 (01) :94-99
[2]   Validation of minimally invasive measurement of myocardial perfusion using electron beam computed tomography and application in human volunteers [J].
Bell, MR ;
Lerman, LO ;
Rumberger, JA .
HEART, 1999, 81 (06) :628-635
[3]   Noninvasive coronary artery Imaging - Magnetic resonance angiography and multidetector computed tomography angiography - A scientific statement from the American Heart Association Committee on cardiovascular imaging and intervention of the council on cardiovascular radiology and intervention, and the councils on clinical cardiology and cardiovascular disease in the young [J].
Bluemke, David A. ;
Achenbach, Stephan ;
Budoff, Matthew ;
Gerber, Thomas C. ;
Gersh, Bernard ;
Hillis, L. David ;
Hundley, W. Gregory ;
Manning, Warren J. ;
Printz, Beth Feller ;
Stuber, Matthias ;
Woodard, Pamela K. .
CIRCULATION, 2008, 118 (05) :586-606
[4]   Diagnostic Performance of 64-Multidetector Row Coronary Computed Tomographic Angiography for Evaluation of Coronary Artery Stenosis in Individuals Without Known Coronary Artery Disease [J].
Budoff, Matthew J. ;
Dowe, David ;
Jollis, James G. ;
Gitter, Michael ;
Sutherland, John ;
Halamert, Edward ;
Scherer, Markus ;
Bellinger, Raye ;
Martin, Arthur ;
Benton, Robert ;
Delago, Augustin ;
Min, James K. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (21) :1724-1732
[5]   Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis [J].
Garcia, Mario J. ;
Lessick, Jonathan ;
Hoffmann, Martin H. K. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (04) :403-411
[6]   Does Coronary Flow Trump Coronary Anatomy? [J].
Gould, K. Lance .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (08) :1009-1023
[7]   Low to Intermediate Probability of Coronary Artery Disease : Comparison of Coronary CT Angiography with First-Pass MR Myocardial Perfusion Imaging [J].
Groothuis, Jan G. J. ;
Beek, Aernout M. ;
Brinckman, Stijn L. ;
Meijerink, Martijn R. ;
Koestner, Simon C. ;
Nijveldt, Robin ;
Gotte, Marco J. W. ;
Hofman, Mark B. M. ;
van Kuijk, Cornelis ;
van Rossum, Albert C. .
RADIOLOGY, 2010, 254 (02) :384-392
[8]   Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease - Patient-versus segment-based analysis [J].
Hoffmann, U ;
Moselewski, F ;
Cury, RC ;
Ferencik, M ;
Jang, IK ;
Diaz, LJ ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
CIRCULATION, 2004, 110 (17) :2638-2643
[9]   Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography [J].
Meijboom, W. Bob ;
Meijs, Matthijs F. L. ;
Schuijf, Joanne D. ;
Cramer, Maarten J. ;
Mollet, Nico R. ;
van Mieghem, Carlos A. G. ;
Nieman, Koen ;
van Werkhoven, Jacob M. ;
Pundziute, Gabija ;
Weustink, Annick C. ;
de Vos, Alexander M. ;
Pugliese, Francesca ;
Rensing, Benno ;
Jukema, J. Wouter ;
Bax, Jeroen J. ;
Prokop, Mathias ;
Doevendans, Pieter A. ;
Hunink, Myriam G. M. ;
Krestin, Gabriel P. ;
de Feyter, Pim J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (25) :2135-2144
[10]   Diagnostic Performance of Coronary Angiography by 64-Row CT [J].
Miller, Julie M. ;
Rochitte, Carlos E. ;
Dewey, Marc ;
Arbab-Zadeh, Armin ;
Niinuma, Hiroyuki ;
Gottlieb, Ilan ;
Paul, Narinder ;
Clouse, Melvin E. ;
Shapiro, Edward P. ;
Hoe, John ;
Lardo, Albert C. ;
Bush, David E. ;
de Roos, Albert ;
Cox, Christopher ;
Brinker, Jeffery ;
Lima, Joao A. C. .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (22) :2324-2336