A statistically defined endpoint titer determination method for Immunoassays

被引:485
作者
Frey, A
Di Canzio, J
Zurakowski, D
机构
[1] Univ Munster, Zentrum Mol Biol Entzundung, Inst Infektiol, D-48149 Munster, Germany
[2] Harvard Univ, Childrens Hosp, Sch Med, Dept Res Comp & Biostat, Boston, MA 02115 USA
关键词
endpoint titer; cutoff; prediction limit; t-statistic;
D O I
10.1016/S0022-1759(98)00170-7
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Results of immunoassays for which no positive standards are available are often expressed as endpoint titers. The endpoint titer is defined as the reciprocal of the highest analyte dilution that gives a reading above the cutoff. Unfortunately, there is no generally accepted rule for the determination of these cutoff values. In enzyme-linked immunosorbent assays (ELISA) a value two or three times the mean background or negative control reading is sometimes used. Other investigators set the cutoff arbitrarily at a certain absorbance value. These procedures do not provide statistically meaningful information about the risk of overtitration or false low titers. We have solved this problem by devising a practical method for establishing a statistically valid cutoff. The procedure involves calculating the upper prediction limit using the Student t-distribution. The mathematical formula which defines the upper prediction limit is expressed as the standard deviation multiplied by a factor which is based on the number of negative controls and the confidence level (1 - alpha). Appropriate factors are provided for 2 to 30 negative controls and for confidence levels ranging from 95% to 99.9%. Our new method is more reliable than other nonstatistical procedures yet does not require sophisticated computation. It can be applied to a variety of immunoassays provided that negative controls are available. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 10 条
[1]
ESTIMATION OF ROTAVIRUS IMMUNOGLOBULIN-G ANTIBODIES IN HUMAN-SERUM SAMPLES BY ENZYME-LINKED IMMUNOSORBENT-ASSAY - EXPRESSION OF RESULTS AS UNITS DERIVED FROM A STANDARD CURVE [J].
BISHOP, RF ;
CIPRIANI, E ;
LUND, JS ;
BARNES, GL ;
HOSKING, CS .
JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 19 (04) :447-452
[2]
DETECTION OF ANTIBODY TO MURINE CYTOMEGALOVIRUS BY ENZYME-LINKED IMMUNOSORBENT AND INDIRECT IMMUNOFLUORESCENCE ASSAYS [J].
CLASSEN, DC ;
MORNINGSTAR, JM ;
SHANLEY, JD .
JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (04) :600-604
[3]
Dixon WJ, 1983, INTRO STAT ANAL, P92
[5]
Peptomer aluminum oxide nanoparticle conjugates as systemic and mucosal vaccine candidates: Synthesis and characterization of a conjugate derived from the C4 domain of HIV-1(MN) gp120 [J].
Frey, A ;
Neutra, MR ;
Robey, FA .
BIOCONJUGATE CHEMISTRY, 1997, 8 (03) :424-433
[6]
STATISTICAL CONSIDERATIONS IN THE QUANTITATION OF SERUM IMMUNOGLOBULIN LEVELS USING THE ENZYME-LINKED-IMMUNOSORBENT-ASSAY (ELISA) [J].
KARPINSKI, KF ;
HAYWARD, S ;
TRYPHONAS, H .
JOURNAL OF IMMUNOLOGICAL METHODS, 1987, 103 (02) :189-194
[7]
MUCOSAL MODEL OF GENITAL IMMUNIZATION IN MALE RHESUS MACAQUES WITH A RECOMBINANT SIMIAN IMMUNODEFICIENCY VIRUS P27 ANTIGEN [J].
LEHNER, T ;
TAO, L ;
PANAGIOTIDI, C ;
KLAVINSKIS, LS ;
BROOKES, R ;
HUSSAIN, L ;
MEYERS, N ;
ADAMS, SE ;
GEARING, AJH ;
BERGMEIER, LA .
JOURNAL OF VIROLOGY, 1994, 68 (03) :1624-1632
[8]
SOKAL RR, 1995, BIOMETRY, P143
[9]
Quantification of immunological membrane reactions employing a digital desk top scanner and standard graphics software [J].
vonOlleschikElbheim, L ;
elBaya, A ;
Schmidt, MA .
JOURNAL OF IMMUNOLOGICAL METHODS, 1996, 197 (1-2) :181-186
[10]
WEINSTEIN MC, 1980, CLIN DECISION ANAL, P84