Antibodies labeled with fluorescence-agent excitable by infrared rays

被引:29
作者
Muguruma, N [1 ]
Ito, S [1 ]
Hayashi, S [1 ]
Taoka, S [1 ]
Kakehashi, H [1 ]
Ii, K [1 ]
Shibamura, S [1 ]
Takesako, K [1 ]
机构
[1] Univ Tokushima, Sch Med, Dept Internal Med 2, Tokushima 7708503, Japan
关键词
indocyanine green (ICG); vital immunohistochemical stain;
D O I
10.1007/s005350050116
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Endoscopy is not significantly better than fiberscopy for the diagnosis of minute cancers of the digestive tract. However, labeling of these lesions with an agent that can be detected videoendoscopically, with subsequent computer processing of the electronic signals, should facilitate endoscopic diagnosis of microlesions. We developed an antibody labeled with an indocyanine green(ICG) derivative that has a specific fluorescence emission at 807 nm upon excitation at 768 nm. The physiochemical characteristics of this labeled antibody resemble those of ICG. The activity of the antibody is suitable for immunohistochemical staining, and the antibody fluoresces under infrared ray excitation. This antibody should prove useful for performing vital immunostaining for infrared endoscopy.
引用
收藏
页码:467 / 471
页数:5
相关论文
共 16 条
  • [1] BJORNSSON OG, 1982, EXPERIENTIA, V38, P1441
  • [2] ULTRAVIOLET-RADIATION DAMAGE IN DNA
    DAVIES, RJH
    [J]. BIOCHEMICAL SOCIETY TRANSACTIONS, 1995, 23 (02) : 407 - 418
  • [3] FOX IJ, 1956, CIRCULATION, V14, P937
  • [4] INTRAGASTRIC INFRARED PHOTOGRAPHY IN CONJUNCTION WITH INFRARED-ABSORPTION ANGIOGRAPHY
    FRANKE, J
    LUX, G
    DEMLING, L
    [J]. GASTROINTESTINAL ENDOSCOPY, 1985, 31 (02) : 87 - 89
  • [5] HEATLEY NG, 1959, GASTROENTEROLOGY, V37, P313
  • [6] DEVELOPMENT OF FLUORESCENCE-EMITTING ANTIBODY LABELING SUBSTANCE BY NEAR-INFRARED RAY EXCITATION
    ITO, S
    MUGURUMA, N
    KAKEHASHI, Y
    HAYASHI, S
    OKAMURA, S
    SHIBATA, H
    OKAHISA, T
    KANAMORI, M
    SHIBAMURA, S
    TAKESAKO, K
    NOZAWA, M
    ISHIDA, K
    SHIGA, M
    [J]. BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 1995, 5 (22) : 2689 - 2694
  • [7] ITO S, 1997, DIGEST ENDOSC, V9, P278
  • [8] KINSEY JH, 1978, MAYO CLIN PROC, V53, P594
  • [9] AN INVESTIGATION OF AN INFRARED RAY ELECTRONIC ENDOSCOPE WITH A LASER DIODE LIGHT-SOURCE
    KOHSO, H
    TATSUMI, Y
    FUJINO, H
    TOKITA, K
    KODAMA, T
    KASHIMA, K
    KAWAI, K
    [J]. ENDOSCOPY, 1990, 22 (05) : 217 - 220
  • [10] COMPUTER-ASSISTED DATA-PROCESSING OF IMAGES OF MUCOSAL AND SUBMUCOSAL BLOOD-VESSELS OF THE STOMACH OBTAINED BY VISIBLE AND INFRARED ENDOSCOPY USING A DIRECTIONAL-CONTRAST FILTER
    OHTA, H
    KOHGO, Y
    TAKAHASHI, Y
    KOYAMA, R
    SUZUKI, H
    NIITSU, Y
    [J]. GASTROINTESTINAL ENDOSCOPY, 1994, 40 (05) : 621 - 628