Survivorship of rough-surfaced threaded acetabular cups - 382 consecutive primary Zweymuller cups followed for 0.2-12 years

被引:32
作者
Delaunay, CP [1 ]
Kapandji, AI [1 ]
机构
[1] Clin Yvette, FR-91160 Longjumeau, France
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1998年 / 69卷 / 04期
关键词
D O I
10.3109/17453679808999050
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied prospectively 382 cementless (Zweymuller stem) and hybrid (cemented stem) primary total hip replacements and used a cementless grit-blasted titanium alloy threaded cup. After a median 5 (0.2-12)-year follow-up, 1 cup was exchanged, 2 cups were removed for deep sepsis, and 3 cups showed definite loosening; of these, 2 subsequently required revision. Actuarial calculation methods indicated a 10-year survivorship of 99% with cup retrieval for any cause (clinical failure), definite cup-loosening (radiographic failure), and revision for aseptic cup-loosening as endpoints, These intermediate results exceed those from smooth-surfaced screw rings and compare favorably with those from cemented cups and cementless, press-fit, metal-backed cups.
引用
收藏
页码:379 / 383
页数:5
相关论文
共 25 条
[1]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[2]  
APEL DM, 1989, CLIN ORTHOP RELAT R, P183
[3]   Pain levels after total hip replacement - Their use as endpoints for survival analysis [J].
Britton, AR ;
Murray, DW ;
Bulstrode, CJ ;
McPherson, K ;
Denham, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (01) :93-98
[4]   FAILURE OF THE MECRING SCREW-RING ACETABULAR COMPONENT IN TOTAL HIP-ARTHROPLASTY - A 3-YEAR TO 7-YEAR FOLLOW-UP-STUDY [J].
BRUIJN, JD ;
SEELEN, JL ;
FEENSTRA, RM ;
HANSEN, BE ;
BERNOSKI, FP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (05) :760-766
[5]  
Dalstra M., 1994, Clinical Materials, V16, P145, DOI 10.1016/0267-6605(94)90110-4
[6]  
DELAUNAY C, 1994, REV CHIR ORTHOP, V80, P388
[7]   THE NEED FOR CONFIDENCE-INTERVALS IN THE PRESENTATION OF ORTHOPEDIC DATA [J].
DOREY, F ;
NASSER, S ;
AMSTUTZ, H .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (12) :1844-1852
[8]  
DUPARC J, 1991, REV CHIR ORTHOP, V77, P221
[9]   HIP-REPLACEMENT WITH A THREADED ACETABULAR CUP - A FOLLOW-UP-STUDY [J].
FOX, GM ;
MCBEATH, AA ;
HEINER, JP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (02) :195-201
[10]   EARLY AND LATE LOOSENING OF THE ACETABULAR CUP AFTER LOW-FRICTION ARTHROPLASTY [J].
GARCIACIMBRELO, E ;
MUNUERA, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (08) :1119-1129