Improved selectivity and stability of glucose biosensor based on in situ electropolymerized polyaniline-polyacrylonitrile composite film

被引:58
作者
Xue, HG [1 ]
Shen, ZQ
Li, CM
机构
[1] Yangzhou Univ, Sch Chem & Chem Engn, Yangzhou 225002, Peoples R China
[2] Zhejiang Univ, Inst Polymer Sci, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
glucose biosensor; in situ electropolymerization; polyaniline-polyacrylonitrile composites; selectivity; stability;
D O I
10.1016/j.bios.2004.07.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new type of in situ electropolymerization method was used for electrochemical biosensor design. The biologic film was prepared by in situ electropolymerization of aniline into microporous polyacrylonitrile-coated platinum electrode in the presence of glucose oxidase. The novel glucose biosensor exhibited good selectivity, sensitivity and stability, which showed no apparent loss of activity after 100 consecutive measurements and intermittent usage for 100 days with storage in a phosphate buffer at 4 degrees C. Blood glucose determinations agreed well with standard hospital laboratory analysis. The construction and operational parameters of the biosensor were also optimized. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:2330 / 2334
页数:5
相关论文
共 18 条
[1]   Oxidase enzyme immobilisation through electropolymerised films to assemble biosensors for batch and flow injection analysis [J].
Badea, M ;
Curulli, A ;
Palleschi, G .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :689-698
[2]   Electropolymerization as a versatile route for immobilizing biological species onto surfaces -: Application to DNA biochips [J].
Bidan, G ;
Billon, M ;
Galasso, K ;
Livache, T ;
Mathis, C ;
Roget, A ;
Torres-Rodriguez, LM ;
Vieil, E .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2000, 89 (2-3) :183-193
[3]  
BRIGHT HJ, 1969, J BIOL CHEM, V244, P2634
[4]   PLASTICIZED POLY(VINYL CHLORIDE) AS A PERMSELECTIVE BARRIER MEMBRANE FOR HIGH-SELECTIVITY AMPEROMETRIC SENSORS AND BIOSENSORS [J].
CHRISTIE, IM ;
TRELOAR, PH ;
VADGAMA, P .
ANALYTICA CHIMICA ACTA, 1992, 269 (01) :65-73
[5]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456
[6]  
Kesting R.E., 1985, SYNTHETIC POLYM MEMB, V2nd
[7]  
Losada J, 2001, ELECTROANAL, V13, P1016, DOI 10.1002/1521-4109(200108)13:12<1016::AID-ELAN1016>3.0.CO
[8]  
2-B
[9]  
MU SL, 1991, J ELECTROANAL CHEM, V304, P7
[10]   APPLICATION OF MICROPOROUS MEMBRANES TO CHEMI-LUMINESCENCE ANALYSIS [J].
NAU, V ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1979, 51 (03) :424-428