Precision of surface measurements for below-knee residua

被引:37
作者
Commean, PK
Smith, KE
Cheverud, JM
Vannier, MW
机构
[1] WASHINGTON UNIV,SCH MED,MALLINCKRODT INST RADIOL,ST LOUIS,MO 63110
[2] WASHINGTON UNIV,SCH MED,DEPT ANAT & NEUROBIOL,ST LOUIS,MO 63110
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 1996年 / 77卷 / 05期
关键词
D O I
10.1016/S0003-9993(96)90037-4
中图分类号
R49 [康复医学];
学科分类号
100215 [康复医学与理疗学];
摘要
Objective: To determine the absolute and relative precision of geometric measurements made of below knee (BK) residua and their BK plaster positive casts using calipers, electromagnetic digitizer, optical surface scanner (OSS), and spiral x-ray computed tomography (SXCT). Design: The experimental measurement protocol for a single measurement session was as follows: Dot markers were placed on the residuum, and volume and distances were measured using water displacement and calipers; residuum was measured using electromagnetic digitizer; residuum was scanned using three-dimensional (3D) OSS; a negative plaster cast of subject's residuum was made; and residuum was scanned using SXCT scanner. These steps were repeated at a second measurement session. Plaster positive casts were constructed and subsequently measured using the same protocol. Participants: Thirteen adult below-knee amputee volunteers (subjects) participated in the study, and nine subjects returned for a second measurement session. The study group consisted of 9 men and 4 women; 10 Caucasians and 3 African Americans. Results: Distance measurements for all measurement devices were repeatable within 1% in vivo and within 0.5% on plaster casts; and volumes were within 1% in vivo and within 0.1% on plaster casts. Distance measurements for each device were precise within 3% in vivo and within 1% on plaster casts; and volumes were within 5% in vivo and within 6% on plaster casts when compared with caliper and water displacement measures. Conclusion: These measurement systems were found to be substantially equivalent in terms of repeatability and precision for measurement of lower extremity residua. (C) 1996 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation
引用
收藏
页码:477 / 486
页数:10
相关论文
共 33 条
[1]
[Anonymous], 1981, Statistical Tables
[2]
[Anonymous], 3 DIMENSIONAL BIOMED
[3]
BEDNARCZYK JH, 1992, ARCH PHYS MED REHAB, V73, P60
[4]
CHADDERTON HC, 1983, PROSTHET ORTHOT INT, V7, P15
[5]
GEOMETRIC DESIGN OF A MULTISENSOR STRUCTURED LIGHT RANGE DIGITIZER [J].
COMMEAN, PK ;
SMITH, KE ;
BHATIA, G ;
VANNIER, MW .
OPTICAL ENGINEERING, 1994, 33 (04) :1349-1358
[6]
COMMEAN PK, 1994, P IMAGE 7 C IM SOC 1, P369
[7]
ELLEPOLA W, 1993, J REHABIL RES DEV, V30, P260
[8]
COMPUTER DESIGNED PROSTHETIC SOCKET FROM ANALYSIS OF COMPUTED-TOMOGRAPHY DATA [J].
FAULKNER, VW ;
WALSH, NE .
JOURNAL OF PROSTHETICS AND ORTHOTICS, 1989, 1 (03) :154-164
[9]
FERNIE GR, 1982, ARCH PHYS MED REHAB, V63, P162
[10]
INSTRUMENT FOR MONITORING STUMP EDEMA AND SHRINKAGE IN AMPUTEES [J].
FERNIE, GR ;
HOLLIDAY, PJ ;
LOBB, RJ .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1978, 2 (02) :69-72