Correlated photon metrology of detectors and sources

被引:10
作者
Cheung, JY [1 ]
Vaughan, MP [1 ]
Mountford, JR [1 ]
Chunnilall, CJ [1 ]
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
来源
QUANTUM COMMUNICATIONS AND QUANTUM IMAGING | 2004年 / 5161卷
关键词
photon countin; detector; calibration; correlated photons; metrology;
D O I
10.1117/12.511956
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Many of the schemes under study for Quantum Information Processing technology based on photon states involve active and passive optical components as well as detectors. In order to able to establish fidelity levels for these schemes, the performance of the optical components and the quantum efficiency (q.e.) of the detectors require careful and accurate characterization. Correlated photons produced from spontaneous parametric downconversion, which are also the basis of entangled photon states, conveniently offer a direct means of measuring detector q.e. in the photon counting regime, while stimulated parametric downconversion can be used to measure source radiance. Detector and source calibration using correlated photon techniques therefore addresses some of the key issues critical to the development of QIP technology and the development of correlated/entangled photon metrology. This paper reports work being undertaken at NPL to establish the accuracy limitations of these correlated photon techniques. Significant sources of uncertainty are the need to measure losses due to any optical components used and the requirement to obtain and maintain good geometrical and spectral alignment.
引用
收藏
页码:365 / 376
页数:12
相关论文
共 25 条
[1]   HIGHLY STABLE, MONOCHROMATIC AND TUNABLE OPTICAL RADIATION SOURCE AND ITS APPLICATION TO HIGH-ACCURACY SPECTROPHOTOMETRY [J].
ANDERSON, VE ;
FOX, NP ;
NETTLETON, DH .
APPLIED OPTICS, 1992, 31 (04) :536-545
[2]  
BOUWMEESTER D, 2000, PHYS QUANTUM INFORMA
[3]   Quantum efficiency and dead time of single-photon counting photodiodes: a comparison between two measurement techniques [J].
Brida, G ;
Castelletto, S ;
Degiovanni, IP ;
Novero, C ;
Rastello, ML .
METROLOGIA, 2000, 37 (05) :625-628
[4]   Measuring absolute infrared spectral radiance with correlated photons: new arrangements for improved uncertainty and extended IR range [J].
Dauler, E ;
Migdall, A ;
Boeuf, N ;
Datla, RU ;
Muller, A ;
Sergienko, A .
METROLOGIA, 1998, 35 (04) :295-300
[5]   RADIOMETRIC ASPECTS OF AN EXPERIMENT TO DETERMINE THE MELTING FREEZING TEMPERATURE OF GOLD [J].
FOX, NP ;
MARTIN, JE ;
NETTLETON, DH .
METROLOGIA, 1991, 28 (03) :221-227
[6]   Primary radiometric quantities and units [J].
Fox, NP .
METROLOGIA, 2000, 37 (05) :507-513
[7]   BELL INEQUALITY FOR POSITION AND TIME [J].
FRANSON, JD .
PHYSICAL REVIEW LETTERS, 1989, 62 (19) :2205-2208
[8]   A wavelength tunable, quasi-cw laser source for high accuracy spectrometric measurement in the 200 nm to 500 nm region [J].
Hartree, WS ;
Theocharous, E ;
Fox, NP .
FOURTH OXFORD CONFERENCE ON SPECTROSCOPY, 2003, 4826 :104-112
[9]   MEASUREMENT OF SUBPICOSECOND TIME INTERVALS BETWEEN 2 PHOTONS BY INTERFERENCE [J].
HONG, CK ;
OU, ZY ;
MANDEL, L .
PHYSICAL REVIEW LETTERS, 1987, 59 (18) :2044-2046
[10]  
HUGHES R, 2002, LAUR026900