Psychometric properties of the national eye institute visual function questionnaire (NEI-VFQ)

被引:658
作者
Mangione, CM
Lee, PP
Pitts, J
Gutierrez, P
Berry, S
Hays, RD
机构
[1] Univ Calif Los Angeles, Dept Med, Div GIM & HSR, MSPH, Los Angeles, CA 90095 USA
[2] Rand Corp, RAND Hlth Program, Santa Monica, CA USA
[3] Univ So Calif, Doheny Eye Inst, Los Angeles, CA USA
[4] Univ So Calif, Dept Ophthalmol, Los Angeles, CA 90089 USA
关键词
D O I
10.1001/archopht.116.11.1496
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To test the reliability and validity of the 51-item Field Test Version of the National Eye Institute Visual Function Questionnaire (NEI-VFQ) across 5 common chronic eye conditions. Design: Prospective observational cohort study of persons with 1 of 5 chronic eye diseases who were scheduled for nonurgent visits in ophthalmology practices or had low vision from any cause, and a reference sample of persons without eye disease. Setting: Six university-based ophthalmology practices and the National Eye Institute Clinical Center, Bethesda, Md. Patients: Eligible participants had to have 1 of the following eye conditions: age-related cataracts, age-related macular degeneration, diabetic retinopathy, primary open-angle glaucoma, cytomegalovirus retinitis, or low vision from any cause. Each of the 7 sites also enrolled persons in a reference sample. Reference sample participants had no evidence of underlying eye disease but were scheduled for either screening eye examinations or correction of refractive error. All eligible persons had to be aged 21 years or older, English speaking, and cognitively able to give informed consent and participate in a health status interview. Measurements and Main Results: To provide the data needed to assess the reliability and validity of the 51-item NEI-VFQ, all subjects completed an interview that consisted of the 51-item NEI-VFQ, the Medical Outcomes Study 36-Item Short-Form Health Survey, and at least 1 measure of vision-targeted functional status, Estimates of internal consistency and test-retest reproducibility indicate that the 51-item NEI-VFQ is reliable. Tests of association with other scales and clinical variables support the construct validity of the survey. Conclusions: In this cross-sectional study, the 51-item NEI-VFQ seems to be reliable and valid and should be a useful tool for group-level comparisons of vision-targeted, health-related quality of life in clinical research. Additionally, the psychometric properties of the NEI-VFQ were not influenced by the type or severity of the underlying eye disease, suggesting that the measure will provide reproducible and valid data when used across multiple eye conditions.
引用
收藏
页码:1496 / 1504
页数:9
相关论文
共 29 条
[1]  
APPLEGATE WB, 1987, JAMA-J AM MED ASSOC, V257, P1064
[2]  
BERNTHPETERSEN P, 1981, ACTA OPHTHALMOL, V59, P198
[3]  
BERNTHPETERSEN P, 1981, ACTA OPHTHALMOL, V59, P50
[4]  
BERRY SH, 1979, VISUAL ENV ADAPTATIO
[5]   VISION CHANGE AND QUALITY-OF-LIFE IN THE ELDERLY - RESPONSE TO CATARACT-SURGERY AND TREATMENT OF OTHER CHRONIC OCULAR CONDITIONS [J].
BRENNER, MH ;
CURBOW, B ;
JAVITT, JC ;
LEGRO, MW ;
SOMMER, A .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (05) :680-685
[6]   SENSORY IMPAIRMENT AND QUALITY-OF-LIFE IN A COMMUNITY ELDERLY POPULATION [J].
CARABELLESE, C ;
APPOLLONIO, I ;
ROZZINI, R ;
BIANCHETTI, A ;
FRISONI, GB ;
FRATTOLA, L ;
TRABUCCHI, M .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1993, 41 (04) :401-407
[7]  
Choplin NT, 1995, VISUAL FIELD TESTING
[8]  
Cronbach LJ, 1951, PSYCHOMETRIKA, V16, P297
[9]   NEW VISUAL-ACUITY CHARTS FOR CLINICAL RESEARCH [J].
FERRIS, FL ;
KASSOFF, A ;
BRESNICK, GH ;
BAILEY, I .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (01) :91-96
[10]   MINI-MENTAL STATE - PRACTICAL METHOD FOR GRADING COGNITIVE STATE OF PATIENTS FOR CLINICIAN [J].
FOLSTEIN, MF ;
FOLSTEIN, SE ;
MCHUGH, PR .
JOURNAL OF PSYCHIATRIC RESEARCH, 1975, 12 (03) :189-198