Does microdamage accumulation affect the mechanical properties of bone?

被引:343
作者
Burr, DB [1 ]
Turner, CH
Naick, P
Forwood, MR
Ambrosius, W
Hasan, MS
Pidaparti, R
机构
[1] Indiana Univ, Sch Med, Dept Anat, Indianapolis, IN 46202 USA
[2] Indiana Univ, Sch Med, Dept Orthoped Surg, Indianapolis, IN 46202 USA
[3] Indiana Univ Purdue Univ, Dept Mech Engn, Indianapolis, IN 46202 USA
[4] Indiana Univ Purdue Univ, Biomech & Biomat Res Ctr, Indianapolis, IN 46202 USA
[5] Indiana Univ, Sch Med, Dept Med, Div Biostat, Indianapolis, IN 46202 USA
[6] Indiana State Univ, Dept Ind & Mech Technol, Terre Haute, IN 47809 USA
关键词
microcrack; bone; fatigue; osteoporosis; fragility;
D O I
10.1016/S0021-9290(98)00016-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
It has never been demonstrated that microcrack accumulation in bone leads to impaired mechanical properties. We hypothesized that microdamage accumulation is positively and linearly correlated with a reduction in bone's elastic modulus. We also tested the hypothesis that damage accumulates more rapidly in tensile cortices, but crack growth is greater in compressive cortices. Canine femurs (n = 26) were tested in four-point cyclic bending under load control until they had lost between 5 and 43% of their stiffness. Ten femurs were used as nonloaded controls. The loaded portion of the bone was stained en bloc with basic fuchsin to detect the presence of microdamage. The number of stained microcracks, their lengths and the area of damaged bone were measured under the microscope. Crack numerical density, surface density, mean crack length, and the percentage of damaged area were calculated. Significant microdamage accumulation was not detected until the bone had lost 15% of its elastic modulus. The relationship between crack density and stiffness loss was approximately quadratic, but the relationship between damaged area and stiffness loss was linear. There were significantly more microcracks in tensile cortices, but on average cracks were significantly longer in compressive cortices. We conclude that microcrack accumulation impairs the mechanical properties of bone by reducing its elastic modulus. We also conclude that damage accumulates more rapidly in tensile cortices, but crack growth is greater in compressive cortices. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:337 / 345
页数:9
相关论文
共 34 条
[1]
[Anonymous], FATIGUE MICROSTRUCT
[2]
BROWN CU, 1996, T ORTHOPEDIC RES SOC, V21, P58
[3]
ALTERATIONS TO THE EN-BLOC BASIC FUCHSIN STAINING PROTOCOL FOR THE DEMONSTRATION OF MICRODAMAGE PRODUCED IN-VIVO [J].
BURR, DB ;
HOOSER, M .
BONE, 1995, 17 (04) :431-433
[4]
BONE REMODELING IN RESPONSE TO INVIVO FATIGUE MICRODAMAGE [J].
BURR, DB ;
MARTIN, RB ;
SCHAFFLER, MB ;
RADIN, EL .
JOURNAL OF BIOMECHANICS, 1985, 18 (03) :189-&
[5]
BONE CREEP-FATIGUE DAMAGE ACCUMULATION [J].
CALER, WE ;
CARTER, DR .
JOURNAL OF BIOMECHANICS, 1989, 22 (6-7) :625-635
[6]
CARTER DR, 1977, CLIN ORTHOP RELAT R, P265
[7]
COMPACT BONE FATIGUE DAMAGE .1. RESIDUAL STRENGTH AND STIFFNESS [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BIOMECHANICS, 1977, 10 (5-6) :325-337
[8]
TENSILE YIELD IN BONE [J].
CURREY, JD ;
BREAR, K .
CALCIFIED TISSUE RESEARCH, 1974, 15 (03) :173-179
[9]
MICRODAMAGE IN RESPONSE TO REPETITIVE TORSIONAL LOADING IN THE RAT TIBIA [J].
FORWOOD, MR ;
PARKER, AW .
CALCIFIED TISSUE INTERNATIONAL, 1989, 45 (01) :47-53
[10]
Frost H., 1960, HENRY FORD HOSP MEDI, V8, P25