Validation of prospective whole-body bone marrow dosimetry by SPECT/CT multimodality imaging in 131I-anti-CD20 rituximab radioimmunotherapy of non-Hodgkin's lymphoma

被引:37
作者
Boucek, JA
Turner, JH
机构
[1] Fremantle Hosp, Dept Nucl Med, Fremantle, WA 6160, Australia
[2] Univ Western Australia, Sch Med & Pharmacol, Nedlands, WA 6009, Australia
关键词
non-Hodgkin's lymphoma; rituximab; radioimmunotherapy; dosimetry; SPECT; CT;
D O I
10.1007/s00259-004-1692-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: Radioimmunotherapy (RIT) for relapsed non-Hodgkin's lymphoma is emerging as a promising treatment strategy. Myelosuppression is the dose-limiting toxicity and may be particularly problematic in patients heavily pretreated with chemotherapy. Reliable dosimetry is likely to minimise toxicity and improve treatment efficacy, and the aim of this study was to elucidate the complex problems of dosimetry of RIT by using an integrated SPECT/CT system. Methods: As a part of a clinical trial of I-131-anti-CD20 rituximab RIT of non-Hodgkin's lymphoma, we employed a patient-specific prospective dosimetry method utilising the whole-body effective half-life of antibody and the patient's ideal weight to calculate the administered activity for RIT corresponding to a prescribed radiation absorbed dose of 0.75 Gy to the whole body. A novel technique of quantitation of bone marrow uptake with hybrid SPECT/CT imaging was developed to validate this methodology by using post-RIT extended imaging and data collection. Results: A strong, statistically significant correlation (p=0.001) between whole-body effective half-life of antibody and effective marrow half-life was demonstrated. Furthermore, it was found that bone marrow activity concentration was proportional to administered activity per unit weight, height or body surface area (p < 0.001). Conclusion: The results of this study show the proposed whole-body dosimetry method to be valid and clinically applicable for safe, effective RIT.
引用
收藏
页码:458 / 469
页数:12
相关论文
共 20 条
[1]
Bolch WE, 2002, J NUCL MED, V43, P97
[2]
Bouchet LG, 2000, J NUCL MED, V41, P189
[3]
Coffey J L, 1979, Med Phys, V6, P307, DOI 10.1118/1.594586
[4]
DeNardo SJ, 1999, J NUCL MED, V40, P302
[5]
Duck A., 1990, PHYS PROPERTIES TISS
[6]
ICRP, 1995, PUBLICATIONS, V70
[7]
Juweid ME, 2002, J NUCL MED, V43, P1507
[8]
A METHOD FOR CONVERSION OF HOUNSFIELD NUMBER TO ELECTRON-DENSITY AND PREDICTION OF MACROSCOPIC PAIR PRODUCTION CROSS-SECTIONS [J].
KNOOS, T ;
NILSSON, M ;
AHLGREN, L .
RADIOTHERAPY AND ONCOLOGY, 1986, 5 (04) :337-345
[9]
ESTIMATION OF RADIATION ABSORBED DOSES TO THE RED MARROW IN RADIOIMMUNOTHERAPY [J].
MACEY, DJ ;
DENARDO, SJ ;
DENARDO, GL ;
DENARDO, DA ;
SHEN, S .
CLINICAL NUCLEAR MEDICINE, 1995, 20 (02) :117-125
[10]
Patton JA, 2000, J NUCL MED, V41, P1364