The aim of this study was to provide the information necessary to enable the comparison of exposure conditions in different human volunteer studies published by the research groups at the Universities of Turku, Swinburne, and Zurich. The latter applied a setup optimized for human volunteer studies in the context of risk assessment while the first two applied a modified commercial mobile phone for which detailed dosimetric data were lacking. While the Zurich Setup exposed the entire cortex of the target hemisphere, the other two setups resulted in only very localized exposure of the upper cheek, and concentrated on a limited area of the middle temporal gyrus just above the ear. The resulting peak spatial SAR averaged over I g of the cortex was 0.19 W/kg of the Swinburne Setup, and 0.31 W/kg for the Turku Setup, compared to I W/kg for the Zurich Setup. The average exposure of the thalamus was 5% and 9% of the Zurich Setup results for the Swinburne and Turku Setups, respectively. In general, the phone-based setup results in only reasonably defined exposures in a very limited area around the maximum exposure; the exposure of the rest of the cortex was low, and may vary greatly as a function of the setup, position, and local anatomy. The analysis confirms the need for a carefully designed exposure setup that exposes the relevant brain areas to a well-defined level in human volunteer studies, and shows that studies can only be properly compared and replicated if sufficiently detailed dosimetric information is available.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 30 条
[1]   Pulsed high-frequency electromagnetic field affects human sleep and sleep electroencephalogram [J].
Borbély, AA ;
Huber, R ;
Graf, T ;
Fuchs, B ;
Gallmann, E ;
Achermann, P .
NEUROSCIENCE LETTERS, 1999, 275 (03) :207-210
[2]  
Burkhardt M, 2000, IEEE T MICROW THEORY, V48, P1927, DOI 10.1109/22.883873
[3]   Suitability of FDTD-based TCAD tools for RF design of mobile phones [J].
Chavannes, N ;
Tay, R ;
Nikoloski, N ;
Kuster, N .
IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2003, 45 (06) :52-66
[4]   Exposure to ELF magnetic and ELF-modulated radiofrequency fields: The time course of physiological and cognitive effects observed in recent studies (2001-2005) [J].
Cook, C. M. ;
Saucier, D. M. ;
Thomas, A. W. ;
Prato, F. S. .
BIOELECTROMAGNETICS, 2006, 27 (08) :613-627
[5]   Acute mobile phone operation affects neural function in humans [J].
Croft, RJ ;
Chandler, JS ;
Burgess, AP ;
Barry, RJ ;
Williams, JD ;
Clarke, AR .
CLINICAL NEUROPHYSIOLOGY, 2002, 113 (10) :1623-1632
[6]  
*ETSI 3GPP, 2005, 100 ETSI 3GPP TS
[7]  
Gabriel C., 1996, Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies, Report N.AL/OE-TR-1996-0037, Occupational and Environmental Health Directorate
[8]   Electromagnetic field emitted by 902 MHz mobile phones shows no effects on children's cognitive function [J].
Haarala, C ;
Bergman, M ;
Laine, M ;
Revonsuo, A ;
Koivisto, M ;
Hämäläinen, H .
BIOELECTROMAGNETICS, 2005, :S144-S150
[9]   902 MHz mobile phone does not affect short term memory in humans [J].
Haarala, C ;
Ek, M ;
Björnberg, L ;
Laine, M ;
Revonsuo, A ;
Koivisto, M ;
Hämäläinen, H .
BIOELECTROMAGNETICS, 2004, 25 (06) :452-456
[10]   Effect of a 902 MHz electromagnetic field emitted by mobile phones on human cognitive function:: A replication study [J].
Haarala, C ;
Björnberg, L ;
Ek, M ;
Laine, M ;
Revonsuo, A ;
Koivisto, M ;
Hämäläinen, H .
BIOELECTROMAGNETICS, 2003, 24 (04) :283-288