A low-cost, programmable device for versatile current delivery in iontophoresis applications

被引:13
作者
Ching, CTS
Camilleri, I
Connolly, P [1 ]
机构
[1] Univ Strathclyde, Bioengn Unit, Glasgow G40 NW, Lanark, Scotland
[2] Glasgow Royal Infirm, Canniesburn Plast Surg Unit, Glasgow G40 SF, Lanark, Scotland
关键词
iontophoresis; reverse iontophoresis; constant current device; drug delivery;
D O I
10.1016/j.snb.2004.07.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
lontophoresis for the localised delivery of drugs through skin or for non-invasive, remote monitoring of patients by extraction of blood-bome components through skin could allow a new generation of medical devices to be developed for low-cost healthcare. Iontophoresis systems in existence today are generally not very portable and too expensive for all world markets. Accordingly, a low-cost, low-power, miniature and programmable device was developed and evaluated which can be programmed to deliver various current profiles during iontophoresis. It can provide a range of current (1-300 mu A) of various signal waveforms (dc, pulsed dc, bipolar de and pulsed bipolar dc) of the type required for iontophoresis. Evaluation showed that this device provides for precise regulation of the magnitude and waveform of a current. The current can be maintained over a wide range of impedance, important for use in medical application, and is independent of the battery voltage. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:534 / 540
页数:7
相关论文
共 21 条
[1]   Control of postoperative pain by transcutaneous electrical nerve stimulation after thoracic operations [J].
Benedetti, F ;
Amanzio, M ;
Casadio, C ;
Cavallo, A ;
Cianci, R ;
Giobbe, R ;
Mancuso, M ;
Ruffini, E ;
Maggi, G .
ANNALS OF THORACIC SURGERY, 1997, 63 (03) :773-776
[2]   Opportunities at the Skin Interface for Continuous Patient Monitoring: A Reverse Iontophoresis Model Tested on Lactate and Glucose [J].
Connolly, Patricia ;
Cotton, Christopher ;
Morin, Fabrice .
IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2002, 1 (01) :37-41
[3]   Suppression of pelvic pain during hysteroscopy with a transcutaneous electrical nerve stimulation device [J].
De Angelis, C ;
Perrone, G ;
Santoro, G ;
Nofroni, I ;
Zichella, L .
FERTILITY AND STERILITY, 2003, 79 (06) :1422-1427
[4]  
DeFelice EA, 1997, STRESS MEDICINE, V13, P31, DOI 10.1002/(SICI)1099-1700(199701)13:1<31::AID-SMI715>3.0.CO
[5]  
2-G
[6]   INVITRO AND INVIVO IONTOPHORESIS OF A TRIPEPTIDE ACROSS NUDE RAT SKIN [J].
GREEN, P ;
SHROOT, B ;
BERNERD, F ;
PILGRIM, WR ;
GUY, RH .
JOURNAL OF CONTROLLED RELEASE, 1992, 20 (03) :209-218
[7]   The treatment of fibromyalgia with cranial electrotherapy stimulation [J].
Lichtbroun, AS ;
Raicer, MMC ;
Smith, RB .
JCR-JOURNAL OF CLINICAL RHEUMATOLOGY, 2001, 7 (02) :72-78
[8]   Noninvasive sampling of phenylalanine by reverse iontophoresis [J].
Merino, V ;
López, A ;
Hochstrasser, D ;
Guy, RH .
JOURNAL OF CONTROLLED RELEASE, 1999, 61 (1-2) :65-69
[9]   Transdermal therapy and diagnosis by iontophoresis [J].
Merino, V ;
Kalia, YN ;
Guy, RH .
TRENDS IN BIOTECHNOLOGY, 1997, 15 (08) :288-290
[10]   NONINVASIVE SAMPLING OF LACTIC-ACID IONS BY IONTOPHORESIS USING CHLORIDE-ION IN THE BODY AS AN INTERNAL STANDARD [J].
NUMAJIRI, S ;
SUGIBAYASHI, K ;
MORIMOTO, Y .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (10) :903-909