Hamstring tendon grafts for reconstruction of the anterior cruciate ligament: Biomechanical evaluation of the use of multiple strands and tensioning techniques

被引:427
作者
Hamner, DL
Brown, CH
Steiner, ME
Hecker, AT
Hayes, WC
机构
[1] Beth Israel Deaconess Med Ctr, Dept Orthopaed Surg, Orthopaed Biomech Lab, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA 02215 USA
关键词
D O I
10.2106/00004623-199904000-00013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Our hypothesis that multiple, equally tensioned strands of hamstring graft used for reconstruction of the anterior cruciate ligament are stronger and stiffer than ten-millimeter patellar ligament grafts was tested biomechanically with use of tendons from cadavera, Methods: In the first part of the study, we measured the strength and stiffness of one, two, and four-strand hamstring grafts, from fresh-frozen cadaveric knees, that had been tensioned equally when clamped, In the second part of the study, we compared four-strand grafts to which tension had been applied by hand and then clamped with similar grafts to which tension had been applied,vith weights and then clamped. The grafts for the two experiments were obtained from thirty-four paired and ten nnpaired knees. We also studied the effects of cooling on the biomechanical properties of grafts by comparing patellar ligament grafts tested at 13 degrees Celsius with those tested at room temperature. Results: Two equally tensioned gracilis strands had 185 percent of the strength and 210 percent of the stiffness (1550 +/- 428 newtons and 336 +/- 141 newtons per millimeter, respectively) of one gracilis strand (837 +/- 138 newtons and 160 +/- 44 newtons per millimeter, respectively). Two equally tensioned semitendinosus strands had 220 percent of the strength and 220 percent of the stiffness (2330 +/- 452 newtons and 469 +/- 185 newtons per millimeter, respectively) of one semitendinosus strand (1060 +/- 227 newtons and 213 +/- 44 newtons per millimeter, respectively). Four combined strands (two gracilis strands and two semitendinosus strands) that were equally tensioned with weights and clamped had the additive tensile properties of the individual strands. With the numbers available, four combined strands that were manually tensioned and clamped were not found to be significantly stronger or stiffer than two semitendinosus strands that were equally tensioned with weights (p > 0.07), Conclusions: Four combined strands that were equally tensioned with weights and clamped were stronger and stiffer than all ten-millimeter patellar ligament grafts that have been described in previous reports. All strands of a hamstring graft must be equally tensioned for the composite to have its optimum biomechanical properties. Clinical Relevance: Because of the well recognized donor-site morbidity associated with the use of patellar ligament grafts for reconstruction of the anterior cruciate ligament, multiple-strand hamstring-tendon grafts have become an increasingly popular choice. Our data demonstrate that equally tensioned four-strand hamstring-tendon grafts have initial tensile properties that are higher than those reported for ten-millimeter patellar-ligament grafts; thus, from a biomechanical point of view, they seem to be a reasonable alternative.
引用
收藏
页码:549 / 557
页数:9
相关论文
共 32 条
[1]   PATELLAR TENDON VERSUS DOUBLED SEMITENDINOSUS AND GRACILIS TENDONS FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
AGLIETTI, P ;
BUZZI, R ;
ZACCHEROTTI, G ;
DEBIASE, P .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (02) :211-218
[2]   HEALING OF THE MEDIAL COLLATERAL LIGAMENT FOLLOWING A TRIAD INJURY - A BIOMECHANICAL AND HISTOLOGICAL STUDY OF THE KNEE IN RABBITS [J].
ANDERSON, DR ;
WEISS, JA ;
TAKAI, S ;
OHLAND, KJ ;
WOO, SLY .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (04) :485-495
[3]   USE OF PATELLAR TENDON AUTOGRAFT FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION IN THE RABBIT - A LONG-TERM HISTOLOGIC AND BIOMECHANICAL STUDY [J].
BALLOCK, RT ;
WOO, SLY ;
LYON, RM ;
HOLLIS, JM ;
AKESON, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (04) :474-485
[4]   BIOMECHANICAL ASSESSMENT OF THE HEALING RESPONSE OF THE RABBIT PATELLAR TENDON AFTER REMOVAL OF ITS CENTRAL 3RD [J].
BEYNNON, BD ;
PROFFER, D ;
DREZ, DJ ;
STANKEWICH, CJ ;
JOHNSON, RJ .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1995, 23 (04) :452-457
[5]   THE EFFECTS OF DONOR AGE AND STRAIN-RATE ON THE BIOMECHANICAL PROPERTIES OF BONE-PATELLAR TENDON-BONE ALLOGRAFTS [J].
BLEVINS, FT ;
HECKER, AT ;
BIGLER, GT ;
BOLAND, AL ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (03) :328-333
[6]   RUPTURE OF THE PATELLAR LIGAMENT AFTER USE OF ITS CENTRAL 3RD FOR ANTERIOR CRUCIATE RECONSTRUCTION - A REPORT OF 2 CASES [J].
BONAMO, JJ ;
KRINICK, RM ;
SPORN, AA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (08) :1294-1297
[7]   HEALING OF THE PATELLAR TENDON AUTOGRAFT AFTER POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION - A PROCESS OF LIGAMENTIZATION - AN EXPERIMENTAL-STUDY IN A SHEEP MODEL [J].
BOSCH, U ;
KASPERCZYK, WJ .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1992, 20 (05) :558-566
[8]  
BROWN CH, 1993, CLIN SPORT MED, V12, P723
[9]  
BURKS R T, 1988, Arthroscopy, V4, P260, DOI 10.1016/S0749-8063(88)80041-0
[10]   EFFECTS OF STRUCTURE AND STRAIN-MEASUREMENT TECHNIQUE ON THE MATERIAL PROPERTIES OF YOUNG HUMAN TENDONS AND FASCIA [J].
BUTLER, DL ;
GROOD, ES ;
NOYES, FR ;
ZERNICKE, RF ;
BRACKETT, K .
JOURNAL OF BIOMECHANICS, 1984, 17 (08) :579-596