Lowering the detection limit of the acetylcholinesterase biosensor using a nanoporous carbon matrix

被引:86
作者
Sotiropoulou, S [1 ]
Chaniotakis, NA [1 ]
机构
[1] Univ Crete, Dept Chem, Analyt Chem Lab, Iraklion 71409, Crete, Greece
关键词
selective concentration; biosensor; picomolar; Dichlorvos;
D O I
10.1016/j.aca.2004.09.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nanostructured carbon matrix has been used for the immobilization and stabilization of the enzyme Eel. AChE. The use of this activated carbon matrix is shown to provide both, significant enzyme stabilization, as well as the means for lowering the detection limit of the biosensor. The enzyme is immobilized by adsorption into the nanostructured conductive carbon, which also acts as the working electrode. The proposed biosensor showed very good stability under continuous operation conditions (L-50 > 60 days), allowing its further use in inhibition mode. Using this biosensor, the monitoring of the organophosphorus pesticide dichlorvos at picomolar levels (1000 times lower than other systems reported so far) was achieved. The linear range of detection in flow injection system was six orders of magnitude (10(-12) to 10(-6) M). It is suggested that the ability of activated carbon to selectively concentrate the pesticide, as well as the enzyme hyperactivity within the nanopores is the reason for the decrease in the detection limit of the biosensor. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 33 条
[1]   A disposable multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution [J].
Bachmann, TT ;
Schmid, RD .
ANALYTICA CHIMICA ACTA, 1999, 401 (1-2) :95-103
[2]   Improved multianalyte detection of organophosphates and carbamates with disposable multielectrode biosensors using recombinant mutants of Drosophila acetylcholinesterase and artificial neural networks [J].
Bachmann, TT ;
Leca, B ;
Vilatte, F ;
Marty, JL ;
Fournier, D ;
Schmid, RD .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4) :193-201
[3]   Sonochemically fabricated microelectrode arrays for biosensors offering widespread applicability: Part I [J].
Barton, AC ;
Collyer, SD ;
Davis, F ;
Gornall, DD ;
Law, KA ;
Lawrence, ECD ;
Mills, DW ;
Myler, S ;
Pritchard, JA ;
Thompson, M ;
Higson, SPJ .
BIOSENSORS & BIOELECTRONICS, 2004, 20 (02) :328-337
[4]   Involvement of deacylation in activation of substrate hydrolysis by Drosophila acetylcholinesterase [J].
Brochier, L ;
Pontié, Y ;
Willson, M ;
Estrada-Mondaca, S ;
Czaplicki, J ;
Klaébé, A ;
Fournier, D .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2001, 276 (21) :18296-18302
[5]   A NEW AND RAPID COLORIMETRIC DETERMINATION OF ACETYLCHOLINESTERASE ACTIVITY [J].
ELLMAN, GL ;
COURTNEY, KD ;
ANDRES, V ;
FEATHERSTONE, RM .
BIOCHEMICAL PHARMACOLOGY, 1961, 7 (02) :88-&
[6]   Amperometric flow-through biosensor for the determination of cholinesterase inhibitors [J].
Evtugyn, GA ;
Ivanov, AN ;
Gogol, EV ;
Marty, JL ;
Budnikov, HC .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :13-21
[7]   Sensitivity and selectivity of electrochemical enzyme sensors for inhibitor determination [J].
Evtugyn, GA ;
Budnikov, HC ;
Nikolskaya, EB .
TALANTA, 1998, 46 (04) :465-484
[8]  
FRANCIS BM, 1994, TOXIC SUBSTANCES ENV, pCH8
[9]   Improved operational stability of biosensors based on enzyme-polyelectrolyte complex adsorbed into a porous carbon electrode [J].
Gavalas, VG ;
Chaniotakis, NA ;
Gibson, TD .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (11) :1205-1211
[10]   Polyelectrolyte stabilized oxidase based biosensors: effect of diethylaminoethyl-dextran on the stabilization of glucose and lactate oxidases into porous conductive carbon [J].
Gavalas, VG ;
Chaniotakis, NA .
ANALYTICA CHIMICA ACTA, 2000, 404 (01) :67-73