Although the analytical literature seems abundant for the determination of metoprolol in human plasma, a method using standard equipment providing a sensitive and simple high-performance liquid chromatographic (HPLC) method for limited blood volume, e.g. where 1 mL of blood in a 1 kg infant equals 70 mL of adult blood volume, has rarely been addressed. Therefore, in 500 mu L of plasma, metoprolol was extracted using an internal standard and solid-phase extraction columns. Chromatographic analysis was performed on a Spherisorb C-6 column (5 mu m particle size) at ambient temperature and fluorimetric detection with an excitation wavelength of 225 nm, and emission wavelength of 310 nm. The mobile phase [30% acetonitrile and 70% 0.25 m potassium acetate buffer (pH 4)] was pumped with I mL/min. Metoprolol recovery was determined at 73.0 +/- 20.5%, and the limit of quantitation was 2.4 ng/mL. Precision values of intra- and inter-assay were below 15.5% and those for accuracy were between 90 and 110%. This method was developed for monitoring and determination of pharmacokinetic parameters of metoprolol in pediatric patients and therefore metoprolol plasma concentrations in a 2-year-old child with ventricular tachycardia are reported. Copyright (c) 2004 John Wiley & Sons, Ltd.
引用
收藏
页码:202 / 207
页数:6
相关论文
共 20 条
[1]   HPLC quantification of carvedilol in small plasma volumes from children [J].
Behn, F ;
Läer, S ;
Mir, TS ;
Scholz, H .
CHROMATOGRAPHIA, 2001, 53 (11-12) :641-644
[2]  
BHATTI MM, 1992, J CHROMATOGR-BIOMED, V579, P361
[3]   ASSESSMENT OF ANEMIA IN NEWBORN-INFANTS [J].
BLANCHETTE, VS ;
ZIPURSKY, A .
CLINICS IN PERINATOLOGY, 1984, 11 (02) :489-510
[4]   Development, validation and analytical error function of two chromatographic methods with fluorimetric detection for the determination of bisoprolol and metoprolol in human plasma [J].
Braza, AJ ;
Modamio, P ;
Lastra, CF ;
Mariño, EL .
BIOMEDICAL CHROMATOGRAPHY, 2002, 16 (08) :517-522
[5]   β-adrenergic receptor blockade in chronic heart failure [J].
Bristow, MR .
CIRCULATION, 2000, 101 (05) :558-569
[6]  
*FOOD DRUG ADM, GEN CONS PED PHARM S
[7]   SOLID-PHASE EXTRACTION AND DIRECT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF METOPROLOL ENANTIOMERS IN PLASMA [J].
HERRING, VL ;
BASTIAN, TL ;
LALONDE, RL .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 567 (01) :221-227
[8]  
ILLING S, 2003, KLINIKLEITFADEN PADI, P356
[9]   Developmental pharmacology - Drug disposition, action, and therapy in infants and children [J].
Kearns, GL ;
Abdel-Rahman, SM ;
Alander, SW ;
Blowey, DL ;
Leeder, JS ;
Kauffman, RE .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (12) :1157-1167
[10]   Small blood volumes from children for quantitative sotalol determination using high-performance liquid chromatography [J].
Läer, S ;
Wauer, I ;
Scholz, H .
JOURNAL OF CHROMATOGRAPHY B, 2001, 753 (02) :421-425