Anterior chamber angle measurement with Anterior Eye Segment analysis system Nidek EAS-1000®:: improving the repeatability

被引:7
作者
Lee, TT [1 ]
Lam, AKC [1 ]
Chan, BLK [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Optometry & Radiog, Hong Kong, Hong Kong, Peoples R China
关键词
anterior chamber angle; EAS-1000 (R) Anterior Eye Segment analysis system; optical axis; visual axis;
D O I
10.1046/j.1475-1313.2003.00133.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Previous studies have reported good intraobserver and interobserver repeatability of anterior chamber angle (ACA) assessment using the Anterior Eye Segment analysis system, EAS-1000((R)). This study investigated the influence of fixation pattern, corneal plotting method and camera position on ACA measurements. A Nidek EAS-1000((R)) system was employed for image acquisition and analysis, to obtain measurements of ACA. Twenty-five young healthy subjects participated. The ACAs were different in different quadrants and using different corneal plotting methods (Repeated measures 3-way ANOVA, p < 0.05). However, the difference was <5degrees and therefore not clinically significant. Alignment along the visual axis or optical axis did not yield any significant difference. Repeatability was improved by asking the subjects to fixate at the flashing light-emitting diode (LED). Temporal and nasal angles also demonstrated better repeatability than vertical angles. In measuring the vertical angles, the camera can be set at either the temporal or nasal side (Paired t-test, p > 0.05). The Anterior Eye Segment analysis system has good clinical repeatability in measuring ACA. It can be further improved with the use of the flashing LED during image acquisition.
引用
收藏
页码:423 / 428
页数:6
相关论文
共 22 条
[1]  
BAEZ KA, 1992, OPHTHALMIC SURG LAS, V23, P426
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
BOKER T, 1995, OPHTHALMIC RES, V27, P104
[4]  
Bosem M E, 1992, J Glaucoma, V1, P254, DOI 10.1097/00061198-199201040-00008
[5]   Anterior chamber angle biometry: quadrant variation, age change and sex difference [J].
Chen, HB ;
Kashiwagi, K ;
Yamabayashi, S ;
Kinoshita, T ;
Ou, B ;
Tsukahara, S .
CURRENT EYE RESEARCH, 1998, 17 (02) :120-124
[6]   Glaucoma [J].
Coleman, AL .
LANCET, 1999, 354 (9192) :1803-1810
[7]  
Devereux JG, 2000, ARCH OPHTHALMOL-CHIC, V118, P257
[8]   Extent and effect of surface tilt on the data display of the EyeSys videokeratoscope [J].
Douthwaite, WA ;
Pardhan, S ;
Burek, H .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (11) :986-993
[9]  
Douthwaite WA, 1998, INVEST OPHTH VIS SCI, V39, P1727
[10]  
EDMUND C, 1987, AM J OPTOM PHYS OPT, V64, P846