Impact of ischemia on left ventricular dyssynchrony by phase analysis of gated single photon emission computed tomography myocardial perfusion imaging

被引:69
作者
AlJaroudi, Wael [1 ]
Koneru, Jayanth [2 ]
Heo, Jaekyeong [2 ]
Iskandrian, Ami E. [2 ]
机构
[1] Cleveland Clin Fdn, Div Cardiovasc Med, Cleveland, OH 44195 USA
[2] Univ Alabama Birmingham, Div Cardiovasc Dis, Birmingham, AL 35294 USA
关键词
Ischemia; dyssynchrony; phase analysis; SPECT; MECHANICAL DYSSYNCHRONY; HEART-FAILURE;
D O I
10.1007/s12350-010-9296-1
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Background. There is increasing awareness of the value of phase analysis of gated tomographic myocardial perfusion imaging in assessing left ventricular (LV) dyssynchrony. A concern repeatedly raised in many studies is whether reversible defects in the stress images "ischemia'' could affect the phase-derived standard deviation and bandwidth, the two commonly used dyssynchrony indices. We hypothesized that the stress and rest images should provide comparable information because the images are acquired 1 hour after the tracer injection. Methods and Results. We studied two groups of patients with normal LV ejection fraction and no fixed perfusion defects. In group-1 (N = 20), the patients had reversible perfusion defects involving > 10% of the LV myocardium and in group-2 (N = 20), the patients had normal images. All patients underwent stress/rest-gated single photon emission computed tomography sestamibi imaging (the stress study was acquired with the lower dose) between January and March 2010. Patients with left bundle branch block or ventricular pacing were excluded. The patients in group-1 had a mean age of 61 +/- 9 years, 65% were men, 75% Caucasians, and 70% had known prior coronary artery disease. The size of the reversible perfusion defect was 20 +/- 13% (range 11%-50%) of the LV myocardium. The rest and stress phase-derived standard deviation (16 +/- 6 degrees vs 18 +/- 8 degrees and 16 +/- 7 degrees vs. 19 +/- 6 degrees) and the rest and stress bandwidth (42 +/- 14 degrees vs 46 +/- 16 degrees and 45 +/- 17 degrees vs 52 +/- 12 degrees), respectively, (P = NS for all) were similar in the two groups. The change (stress-rest) in standard deviation and bandwidth in groups 1 and 2 were not statistically significant (0.2 +/- 3.1 degrees vs 1.4 +/- 4.7 degrees, and 2 +/- 13 degrees vs 5 +/- 13 degrees, respectively, P = NS). There was no significant change from rest to stress in the standard deviation and the bandwidth in group-1 (P = .8 and .4, respectively) and group-2 (P = .2 and .08, respectively). There was no correlation between the size of the reversible perfusion defect and the change in phase standard deviation or bandwidth (r = 0.07 and 0.12, respectively, P = NS). Conclusions. The presence of even a large reversible perfusion defect does not alter the indices of mechanical dyssynchrony by phase analysis. Further, comparable information is obtained whether using a low dose or a high dose of the radiotracer. (J Nucl Cardiol 2011;18:36-42.)
引用
收藏
页码:36 / 42
页数:7
相关论文
共 19 条
[1]
Long-term effectiveness of cardiac resynchronization therapy in patients with refractory heart failure and "narrow" QRS [J].
Achilli, A ;
Sassara, M ;
Ficili, S ;
Pontillo, D ;
Achilli, P ;
Alessi, C ;
De Spirito, S ;
Guerra, R ;
Patruno, N ;
Serra, F .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (12) :2117-2124
[2]
Impact of left ventricular dyssynchrony by phase analysis on cardiovascular outcomes in patients with end-stage renal disease [J].
AlJaroudi, Wael ;
Aggarwal, Himanshu ;
Venkataraman, Rajesh ;
Heo, Jaekyeong ;
Iskandrian, Ami E. ;
Hage, Fadi G. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (06) :1058-1064
[3]
Relation of left-ventricular dyssynchrony by phase analysis of gated SPECT images and cardiovascular events in patients with implantable cardiac defibrillators [J].
AlJaroudi, Wael A. ;
Hage, Fadi G. ;
Hermann, Daniel ;
Doppalapudi, Harish ;
Venkataraman, Rajesh ;
Heo, Jaekyeong ;
Iskandrian, Ami E. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (03) :398-404
[4]
Use of phase analysis of gated SPECT perfusion imaging to quantify dyssynchrony in patients with mild-to-moderate left ventricular dysfunction [J].
Atchley, Allen E. ;
Trimble, Mark A. ;
Samad, Zainab ;
Shaw, Linda K. ;
Pagnanelli, Robert ;
Chen, Ji ;
Garcia, Ernest V. ;
Iskandrian, Ami E. ;
Velazquez, Eric J. ;
Borges-Neto, Salvador .
JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (06) :888-894
[5]
Quantitative assessment of myocardial perfusion abnormality on SPECT myocardial perfusion imaging is more reproducible than expert visual analysis [J].
Berman, Daniel S. ;
Kang, Xingping ;
Gransar, Heidi ;
Gerlach, James ;
Friedman, John D. ;
Hayes, Sean W. ;
Thomson, Louise E. J. ;
Hachamovitch, Rory ;
Shaw, Leslee J. ;
Slomka, Piotr J. ;
De Yang, Ling ;
Germano, Guido .
JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (01) :45-53
[6]
Should mechanical dyssynchrony be assessed in patients with implantable cardioverter-defibrillators? [J].
Boogers, Mark J. ;
Schalij, Martin J. ;
Bax, Jeroen J. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (03) :354-358
[7]
Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: Development of a diagnostic tool for assessment of cardiac mechanical dyssynchrony [J].
Chen, J ;
Garcia, EV ;
Folks, RD ;
Cooke, CD ;
Faber, TL ;
Tauxe, L ;
Iskandrian, AE .
JOURNAL OF NUCLEAR CARDIOLOGY, 2005, 12 (06) :687-695
[8]
Temporal resolution of multiharmonic phase analysis of ECG-gated myocardial perfusion SPECT studies [J].
Chen, Ji ;
Faber, Tracy L. ;
Cooke, C. David ;
Garcia, Ernest V. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2008, 15 (03) :383-391
[9]
Corridor4DM: The Michigan method for quantitative nuclear cardiology [J].
Ficaro, Edward P. ;
Lee, Benjamin C. ;
Kritzman, James N. ;
Corbett, James R. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) :455-465
[10]
GERMANO G, 1995, J NUCL MED, V36, P2138