Characterization of asymmetric ceramic membranes by modified permporometry

被引:31
作者
Huang, P
Xu, NP
Shi, J
Lin, YS
机构
[1] NANJING UNIV CHEM TECHNOL,DEPT CHEM ENGN,NANJING 210009,PEOPLES R CHINA
[2] UNIV CINCINNATI,DEPT CHEM ENGN,CINCINNATI,OH 45221
基金
中国国家自然科学基金;
关键词
pore size distribution; active pore size; permporometry; inorganic membrane; ceramic membrane; ultrafiltration;
D O I
10.1016/0376-7388(96)00097-X
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A simple permporometry method based on varying membrane temperature is demonstrated for measuring the pore size distribution of active layer in asymmetric ceramic membranes, This modified permporometry technique can be used to characterize asymmetric ceramic membranes with pores of 2 to 100 nm in diameter. The pore size distribution data of the gamma-Al2O3 membranes measured by the modified permporometry using cyclohexane and carbon tetrachloride as condensable vapor agree favorably with those measured by the nitrogen adsorption porosimetry and permporometry data reported in the literature.
引用
收藏
页码:301 / 305
页数:5
相关论文
共 10 条
[1]   PERMPOROMETRY STUDY ON THE SIZE DISTRIBUTION OF ACTIVE PORES IN POROUS CERAMIC MEMBRANES [J].
CAO, GZ ;
MEIJERINK, J ;
BRINKMAN, HW ;
BURGGRAAF, AJ .
JOURNAL OF MEMBRANE SCIENCE, 1993, 83 (02) :221-235
[2]   A COMPARATIVE-STUDY ON THERMAL AND HYDROTHERMAL STABILITY OF ALUMINA, TITANIA AND ZIRCONIA MEMBRANES [J].
CHANG, CH ;
GOPALAN, R ;
LIN, YS .
JOURNAL OF MEMBRANE SCIENCE, 1994, 91 (1-2) :27-45
[3]   PERMPOROMETRY - THE DETERMINATION OF THE SIZE DISTRIBUTION OF ACTIVE PORES IN UF MEMBRANES [J].
CUPERUS, FP ;
BARGEMAN, D ;
SMOLDERS, CA .
JOURNAL OF MEMBRANE SCIENCE, 1992, 71 (1-2) :57-67
[4]  
CUPERUS FP, 1987, P INT WORKSH CHAR UL, P115
[5]  
EYRAUD C, 1984, B SOC CHIM FR, V9, P1
[6]  
FAIN DE, 1989, P 1 INT C IN MEMBR M, P199
[7]   CHARACTERIZATION OF CERAMIC MEMBRANES .1. THERMAL AND HYDROTHERMAL STABILITIES OF COMMERCIAL 40 ANGSTROM MEMBRANES [J].
GALLAHER, GR ;
LIU, PKT .
JOURNAL OF MEMBRANE SCIENCE, 1994, 92 (01) :29-44
[8]   NEW INSIGHTS INTO THE STRUCTURE OF MICROPOROUS MEMBRANES OBTAINED USING A NEW PORE-SIZE EVALUATION METHOD [J].
KATZ, MG ;
BARUCH, G .
DESALINATION, 1986, 58 (03) :199-211
[9]   IMPROVEMENT OF THERMAL-STABILITY OF POROUS NANOSTRUCTURED CERAMIC MEMBRANES [J].
LIN, YS ;
CHANG, CH ;
GOPALAN, R .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1994, 33 (04) :860-870
[10]   DETERMINATION OF PORE-SIZE AND PORE-SIZE DISTRIBUTION .39 FILTRATION MEMBRANES [J].
NAKAO, S .