Use of a subcutaneous glucose sensor to detect decreases in glucose concentration prior to observation in blood

被引:81
作者
ThomeDuret, V
Reach, G
Gangnerau, MN
Lemonnier, F
Klein, JC
Zhang, YN
Hu, YB
Wilson, GS
机构
[1] HOP HOTEL DIEU,SERV DIABETOL,INSERM U341,F-75181 PARIS,FRANCE
[2] ECOLE MINES,FONTAINEBLEAU,FRANCE
[3] UNIV KANSAS,DEPT CHEM,LAWRENCE,KS 66045
关键词
D O I
10.1021/ac960069i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a hypoglycemic alarm system using a subcutaneous glucose sensor implies that a decrease in blood glucose is rapidly followed by a decrease in the signal generated by the sensor, In a first set of experiments, the linearity and the kinetics of the response of sensors implanted in the subcutaneous tissue of normal rats were investigated during a progressive increase in plasma glucose concentration: the sensitivities determined between 5 and 10 mM and between 10 and 15 mM were not significantly different, and a 5-10 min delay in the sensor's response was observed. In a second set of experiments, performed in diabetic rats, the kinetics of the decrease in subcutaneous glucose concentration following insulin administration was monitored during a decrease in plasma glucose level, from 15 to 3 mmol/L. During the 20 first min following insulin-administration, the sensor monitored glucose concentration in subcutaneous tissue with no lag time, Subsequently, the decrease in the estimation of subcutaneous glucose concentration preceded that of plasma glucose, This phenomenon was not observed when the same sensors were investigated in vitro during a similar decrease in glucose concentration and may be due to a mechanism occurring in vivo, such as the effect of insulin on glucose transfer from the interstitial space to the cells surrounding the sensor, It reinforces the interest of the use of implantable glucose sensors as a part of a hypoglycemic alarm.
引用
收藏
页码:3822 / 3826
页数:5
相关论文
共 26 条
  • [1] CUTANEOUS BLOOD-FLOW DURING A HYPOGLYCEMIC CLAMP IN INSULIN-DEPENDENT DIABETIC-PATIENTS AND HEALTHY-SUBJECTS
    AMAN, J
    BERNE, C
    EWALD, U
    TUVEMO, T
    [J]. CLINICAL SCIENCE, 1992, 82 (06) : 615 - 618
  • [2] DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING
    BINDRA, DS
    ZHANG, YN
    WILSON, GS
    STERNBERG, R
    THEVENOT, DR
    MOATTI, D
    REACH, G
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1692 - 1696
  • [3] LONG-TERM CONTINUOUS GLUCOSE MONITORING WITH MICRODIALYSIS IN AMBULATORY INSULIN-DEPENDENT DIABETIC-PATIENTS
    BOLINDER, J
    UNGERSTEDT, U
    ARNER, P
    [J]. LANCET, 1993, 342 (8879) : 1080 - 1085
  • [4] EFFECTS OF INSULIN ON HUMAN ADIPOSE-TISSUE METABOLISM INVIVO
    COPPACK, SW
    FRAYN, KN
    HUMPHREYS, SM
    DHAR, H
    HOCKADAY, TDR
    [J]. CLINICAL SCIENCE, 1989, 77 (06) : 663 - 670
  • [5] ASSESSMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATION - VALIDATION OF THE WICK TECHNIQUE AS A REFERENCE FOR IMPLANTED ELECTROCHEMICAL SENSORS IN NORMAL AND DIABETIC DOGS
    FISCHER, U
    ERTLE, R
    ABEL, P
    REBRIN, K
    BRUNSTEIN, E
    VONDORSCHE, HH
    FREYSE, EJ
    [J]. DIABETOLOGIA, 1987, 30 (12) : 940 - 945
  • [6] FISCHER U, 1989, J ARTIF ORGANS, V85, P453
  • [7] METABOLIC CHARACTERISTICS OF HUMAN ADIPOSE-TISSUE INVIVO
    FRAYN, KN
    COPPACK, SW
    HUMPHREYS, SM
    WHYTE, PL
    [J]. CLINICAL SCIENCE, 1989, 76 (05) : 509 - 516
  • [8] JANLESWAIN E, 1988, J AM SOC ARTIF INT O, V16, P67
  • [9] CHARACTERIZATION BY MICRODIALYSIS OF INTERCELLULAR GLUCOSE LEVEL IN SUBCUTANEOUS TISSUE IN HUMANS
    JANSSON, PA
    FOWELIN, J
    SMITH, U
    LONNROTH, P
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (02): : E218 - E220
  • [10] KLEIN JC, 1995, HORM METAB RES, V27, P58