Comparison of electroencephalographic dipoles of interictal spikes from prolonged scalp video-electroencephalography and magnetoencephalographic dipoles from short-term recording in children with extratemporal lobe epilepsy

被引:18
作者
Ochi, A
Otsubo, H
Sharma, R
Hunjan, A
Rutka, JT
Chuang, SH
Kamijo, K
Yamazaki, T
Quint, P
Kurelowech, L
Sobel, DF
Aung, MH
Snead, OC
机构
[1] Hosp Sick Children, Dept Paediat, Div Neurol, Toronto, ON M5G 1X8, Canada
[2] Hosp Sick Children, Dept Surg, Toronto, ON M5G 1X8, Canada
[3] Hosp Sick Children, Dept Diagnost Imaging, Toronto, ON M5G 1X8, Canada
[4] Bloorview Epilepsy Res Program, Toronto, ON, Canada
[5] Univ Toronto, Toronto, ON, Canada
[6] NEC Corp Ltd, Fundamental Res Labs, Tsukuba, Ibaraki 305, Japan
[7] Scripps Clin, Magnet Source Imaging Ctr, La Jolla, CA USA
关键词
D O I
10.1177/088307380101600907
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We retrospectively compared electroencephalographic (EEG) dipoles of interictal spikes from prolonged video-EEG monitoring with magnetoencephalographic dipoles from short-term recording in four children with extratemporal lobe epilepsy. We analyzed both sets of dipoles using individual interictal spikes and single moving dipole modeling and evaluated the profiles of spike appearance, dipole position, and orientation in EEG and magnetoencephalography. We obtained more than 100 magnetoencephalographic spikes in two patients who manifested frequent interictal EEG spikes throughout both day and night but fewer than 40 magnetoencephalographic spikes in two patients who had interictal EEG spikes mainly during sleep. The dipole positions of EEG and magnetoencephalography were in close proximity and included in the surgical resection area. Most of the dipoles between EEG and magnetoencephalography were oriented perpendicularly. A combination of EEG dipole analysis from prolonged video-EEG monitoring and magnetoencephalographic dipole analysis provides complementary information for presurgical evaluation in children with intractable extratemporal lobe epilepsy.
引用
收藏
页码:661 / 667
页数:7
相关论文
共 30 条
[1]   Continuous source imaging of scalp ictal rhythms in temporal lobe epilepsy [J].
Assaf, BA ;
Ebersole, JS .
EPILEPSIA, 1997, 38 (10) :1114-1123
[2]   Dipole modeling in epilepsy surgery candidates [J].
Boon, P ;
DHave, M ;
Adam, C ;
Vonck, K ;
Baulac, M ;
Vandekerckhove, T ;
DeReuck, J .
EPILEPSIA, 1997, 38 (02) :208-218
[3]   Possibilities and limitations of magnetic source imaging of methohexital-induced epileptiform patterns in temporal lobe epilepsy patients [J].
Brockhaus, A ;
Lehnertz, K ;
Wienbruch, C ;
Kowalik, A ;
Burr, W ;
Elbert, T ;
Hoke, M ;
Elger, CE .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 102 (05) :423-436
[4]  
CUFFIN BN, 1979, ELECTROEN CLIN NEURO, V47, P132, DOI 10.1016/0013-4694(79)90215-3
[5]  
Gallen C C, 1995, Neuroimaging Clin N Am, V5, P227
[6]   ELECTROENCEPHALOGRAPHIC SPIKING ACTIVITY, DRUG LEVELS, AND SEIZURE OCCURRENCE IN EPILEPTIC PATIENTS [J].
GOTMAN, J ;
MARCIANI, MG .
ANNALS OF NEUROLOGY, 1985, 17 (06) :597-603
[7]   INTERICTAL SPIKING INCREASES AFTER SEIZURES BUT DOES NOT AFTER DECREASE IN MEDICATION [J].
GOTMAN, J ;
KOFFLER, DJ .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1989, 72 (01) :7-15
[8]   Clonidine- and methohexital-induced epileptiform discharges detected by magnetoencephalography (MEG) in patients with localization-related epilepsies [J].
Kirchberger, K ;
Schmitt, H ;
Hummel, C ;
Peinemann, A ;
Pauli, E ;
Kettenmann, B ;
Stefan, H .
EPILEPSIA, 1998, 39 (10) :1104-1112
[9]   Magnetoencephalography in partial epilepsy: Clinical yield and localization accuracy [J].
Knowlton, RC ;
Laxer, KD ;
Aminoff, MJ ;
Roberts, TPL ;
Wong, STC ;
Rowley, HA .
ANNALS OF NEUROLOGY, 1997, 42 (04) :622-631
[10]   Source localization determined by magnetoencephalography and electroencephalography in temporal lobe epilepsy: Comparison with electrocorticography: Technical case report [J].
Ko, DY ;
Kufta, C ;
Scaffidi, D ;
Sato, S .
NEUROSURGERY, 1998, 42 (02) :414-421