摘要
A seven-channel multibiosensor for simultaneous amperometric and potentiometric operation is described. The transducer is fabricated by screen-printing techniques in thick-film technology and contains 14 gold electrodes, which act as working and counter electrodes, and one silver electrode, which is chlorinated to give an integrated silver/silver chloride reference electrode. The ion-selective membranes are based on a poly(vinyl chloride)-poly( vinyl acetate) copolymer. Entrapment of enzymes is achieved by membranes made from organic-solvent-free aqueous polymer dispersions, which can be applied to the sensor electrodes by screen-printing or solder dispenser systems. The sensor is integrated into a flow-injection-analysis (FIA) system and is applied to the analysis of blood serum electrolyte (K+, Li+) and metabolite (glucose, urea, lactate) status.
引用
收藏
页码:127 / 132
页数:6
相关论文
共 16 条
[1]  
BECHTOLD F, 1989, TECH MESS, V56, P264
[2]   POTENTIOMETRIC THICK-FILM SENSOR FOR THE DETERMINATION OF THE NEUROTRANSMITTER ACETYLCHOLINE [J].
EPPELSHEIM, C ;
HAMPP, N .
ANALYST, 1994, 119 (10) :2167-2171
[3]   EVALUATION OF AN OVERDETERMINED SYSTEM BASED ON MULTIPLE ION-SELECTIVE ELECTRODES OF THE SAME TYPE [J].
GLAZIER, SA ;
ARNOLD, MA ;
GLAZIER, JP .
TALANTA, 1988, 35 (03) :215-219
[4]   DESIGN AND APPLICATION OF THICK-FILM MULTISENSORS [J].
HAMPP, N ;
EPPELSHEIM, C ;
POPP, J ;
BISENBERGER, M ;
BRAUCHLE, C .
SENSORS AND ACTUATORS A-PHYSICAL, 1992, 31 (1-3) :144-148
[5]   AN INTEGRATED MULTIBIOSENSOR FOR SIMULTANEOUS AMPEROMETRIC AND POTENTIOMETRIC MEASUREMENT [J].
KIMURA, J ;
MURAKAMI, T ;
KURIYAMA, T ;
KARUBE, I .
SENSORS AND ACTUATORS, 1988, 15 (04) :435-443
[6]   MULTISENSOR ARRAY FOR PH, K+, NA+ AND CA2+ MEASUREMENTS BASED ON COATED-FILM ELECTRODES [J].
LEMKE, U ;
CAMMANN, K ;
KOTTER, C ;
SUNDERMEIER, C ;
KNOLL, M .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :488-491
[7]   MODEL STUDIES ON MULTIPLE CHANNEL ANALYSIS OF FREE MAGNESIUM, CALCIUM, SODIUM, AND POTASSIUM AT PHYSIOLOGICAL CONCENTRATION LEVELS WITH ION-SELECTIVE ELECTRODES [J].
OTTO, M ;
THOMAS, JDR .
ANALYTICAL CHEMISTRY, 1985, 57 (13) :2647-2651
[8]  
PACE SJ, 1992, ACS SYM SER, V487, P261
[9]   SANDWICH ENZYME MEMBRANES FOR AMPEROMETRIC MULTI-BIOSENSOR APPLICATIONS - IMPROVEMENT OF LINEARITY AND REDUCTION OF CHEMICAL CROSS-TALK [J].
POPP, J ;
SILBER, A ;
BRAUCHLE, C ;
HAMPP, N .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (3-4) :243-249
[10]  
PRUDENZIATI M, 1991, SENSOR ACTUAT A-PHYS, V25, P227