Stiffness properties of the human lumbar spine: A lumped parameter model

被引:18
作者
Nicholson, L
Maher, C
Adams, R
Phan-Thien, N
机构
[1] Univ Sydney, Fac Hlth Sci, Sch Physiotherapy, Lidcombe, NSW 2141, Australia
[2] Natl Univ Singapore, Dept Mech Engn, Singapore 117548, Singapore
关键词
measurements; perception; viscosity; stiffness and tests;
D O I
10.1016/S0268-0033(00)00117-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To characterise with a mechanical model, the force-displacement response of the human lumbar spine to posteroanterior loading. Design. Single case with repetition, Background Previous attempts to characterise the spine's force-displacement response have been simplistic and only considered the loading curve. These approaches ignored valuable information such as viscosity, non-linear elasticity and inertia of the lumbar spine. Methods. The Spinal Assessment Machine applied a postero-anterior load to the spines of 23 asymptomatic subjects and measured the force-displacement response. The data was analysed by two methods; by a traditional linear regression of part of the loading curve and by a new method where an equation including non-linear stiffness and damping was used to characterise the whole force-displacement relationship. Results. The equation developed was found to account for virtually all of the variance in the raw data (R-2 > 0.993). Four elements derived by the equation determine the contributions of linear elasticity, non-linear elasticity, linear viscosity and non-linear viscosity to the overall stiffness. Conclusions. Considering the excellent fit of the new equation to the raw data and its poor correlation with existing measures, it is proposed that the traditional measures provide an incomplete description of the force-displacement response.
引用
收藏
页码:285 / 292
页数:8
相关论文
共 28 条
[1]  
Allison GT, 1998, J MANIP PHYSIOL THER, V21, P534
[2]  
BEAUMONT A, 1991, P 7 BIENN C MAN PHYS, P244
[3]  
Fung Y., 1972, Biomechanics: Its Foundations and Objectives
[4]   Variability of forces applied by experienced therapists during spinal mobilization [J].
Harms, MC ;
Bader, DL .
CLINICAL BIOMECHANICS, 1997, 12 (06) :393-399
[5]  
JOHNS RICHARD J., 1964, BIORHEOLOGY, V2, P87
[6]   MECHANICAL-BEHAVIOR OF THE HUMAN LUMBAR SPINE .1. CREEP ANALYSIS DURING STATIC COMPRESSIVE LOADING [J].
KELLER, TS ;
SPENGLER, DM ;
HANSSON, TH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (04) :467-478
[7]  
Latimer J, 1998, J MANIP PHYSIOL THER, V21, P157
[8]   Evaluation of a new device for measuring responses to posteroanterior forces in a patient population .1. Reliability testing [J].
Latimer, J ;
Goodsell, MM ;
Lee, M ;
Maher, CG ;
Wilkinson, BN ;
Moran, CC .
PHYSICAL THERAPY, 1996, 76 (02) :158-165
[9]  
Latimer J., 1996, Man Ther, V1, P266, DOI 10.1054/math.1996.0277
[10]  
Latimer J, 1997, J Manipulative Physiol Ther, V20, P315