Metabolic modelling of full-scale biological nitrogen and phosphorus removing WWTP's

被引:97
作者
Meijer, SCF [1 ]
Van Loosdrecht, MCM [1 ]
Heijnen, JJ [1 ]
机构
[1] Delft Univ Technol, Kluyver Lab, NL-2628 BC Delft, Netherlands
关键词
activated sludge; metabolic; modelling; biological nitrogen; phosphorus; calibration;
D O I
10.1016/S0043-1354(00)00567-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper evaluates the experiences with modelling Full-scale biological phosphorus and nitrogen removing wastewater treatment plants. For the simulation. we used a metabolic phosphorus model integrated in ASM2d, further referred to as TUDP-model. It was round that the metabolic model For bio-P removal can be applied for modelling full-scale wwtp's, without extensive parameter adjustments. A stepwise modelling approach was proposed. Only three specific parameters were calibrated. Two parameters, the inert fraction in the influent and the actual anoxic sludge fraction will need calibration for all systems. parameter sensitivity analyses showed that the sensitivity of operational data. often considered as known input data, is high. The model kinetics were round less sensitive. This a ill in general be the case for all low-loaded wwtp's recorded in their pseudo-steady state. Based on mass balance calculations, operational data and measurements were evaluated. Since all term on a phosphorus balance can be measured, errors in operational data (e.g. SRT and flow rates) become very apparent in P-removal models (ASM2d, TUDP). We suggest using the P-balance in general for wwtp modelling. as a check on data consistency. This study showed that considering operational data per definition as known input data is not justified. Therefore, operational data should he evaluated. or considered in model calibration over the use of kinetic and stoichiometric parameters. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2711 / 2723
页数:13
相关论文
共 25 条
[1]   Analysis and design of suitable model structures for activated sludge tanks with circulating flow [J].
Alex, J ;
Tschepetzki, R ;
Jumar, U ;
Obenaus, F ;
Rosenwinkel, KH .
WATER SCIENCE AND TECHNOLOGY, 1999, 39 (04) :55-60
[2]  
ALEX J, 1997, USERS MANUAL
[3]  
[Anonymous], 1991, MAPLE 5 LANGUAGE REF
[4]   Modeling COD, N and P removal in a full-scale wwtp Haarlem Waarderpolder [J].
Brdjanovic, D ;
Van Loosdrecht, MCM ;
Versteeg, P ;
Hooijmans, CM ;
Alaerts, GJ ;
Heijnen, JJ .
WATER RESEARCH, 2000, 34 (03) :846-858
[5]   Modeling hydrolysis processes considering intracellular storage [J].
Goel, R ;
Mino, T ;
Satoh, H ;
Matsuo, T .
WATER SCIENCE AND TECHNOLOGY, 1999, 39 (01) :97-105
[6]   Comparison of hydrolytic enzyme systems in pure culture and activated sludge under different electron acceptor conditions [J].
Goel, R ;
Mino, T ;
Satoh, H ;
Matsuo, T .
WATER SCIENCE AND TECHNOLOGY, 1998, 37 (4-5) :335-343
[7]   Activated Sludge Model No. 3 [J].
Gujer, W ;
Henze, M ;
Mino, T ;
van Loosdrecht, M .
WATER SCIENCE AND TECHNOLOGY, 1999, 39 (01) :183-193
[8]  
HAO X, 2001, IN PRESS J ENV ENG, V127
[9]   Activated Sludge Model No.2d, ASM2d [J].
Henze, M ;
Gujer, W ;
Mino, T ;
Matsuo, T ;
Wentzel, MC ;
Marais, GVR ;
Van Loosdrecht, MCM .
WATER SCIENCE AND TECHNOLOGY, 1999, 39 (01) :165-182
[10]  
Murnleitner E, 1997, BIOTECHNOL BIOENG, V54, P434