Autocorrelation of integrated power Doppler signals and its application

被引:20
作者
Chen, JF [1 ]
Fowlkes, JB [1 ]
Carson, PL [1 ]
Rubin, JM [1 ]
Adler, RS [1 ]
机构
[1] UNIV MICHIGAN,CTR MED,DEPT RADIOL,ANN ARBOR,MI 48109
关键词
autocorrelation function; power Doppler signal; ultrasound;
D O I
10.1016/S0301-5629(96)00141-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The integrated power Doppler signal arising from blood flow is a random process, In this article, a general approach to model this random process is studied, Both the theoretical and experimental results show that the temporal autocorrelation function of the integrated power Doppler signals is directly related to properties of the insonified medium, such as the scattering strengths and velocities of all moving scatterers, and as well as the properties of the Doppler imaging system, such as the point spread function (psf) of the power Doppler images, Some initial experiments are performed to test the proposed model, Its potential application for flow measurement, such as perfusion evaluation, is also discussed. Copyright (C) 1996 World Federation for Ultrasound in Medicine & Biology
引用
收藏
页码:1053 / 1057
页数:5
相关论文
共 8 条
  • [1] ULTRASONIC ESTIMATION OF TISSUE PERFUSION - A STOCHASTIC APPROACH
    ADLER, RS
    RUBIN, JM
    FOWLKES, JB
    CARSON, PL
    PALLISTER, JE
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (04) : 493 - 500
  • [2] NON-GAUSSIAN VERSUS NON-RAYLEIGH STATISTICAL PROPERTIES OF ULTRASOUND ECHO SIGNALS
    CHEN, JF
    ZAGZEBSKI, JA
    MADSEN, EL
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (04) : 435 - 440
  • [3] A UNIFIED APPROACH TO MODELING THE BACKSCATTERED DOPPLER ULTRASOUND FROM BLOOD
    MO, LYL
    COBBOLD, RSC
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (05) : 450 - 461
  • [4] Papoulis A., 1984, Probability, Random Variables and Stochastic Processes, V2nd
  • [5] FRACTIONAL MOVING BLOOD-VOLUME - ESTIMATION WITH POWER DOPPLER US
    RUBIN, JM
    ADLER, RS
    FOWLKES, JB
    SPRATT, S
    PALLISTER, JE
    CHEN, JF
    CARSON, PL
    [J]. RADIOLOGY, 1995, 197 (01) : 183 - 190
  • [6] RUBIN JM, 1993, DIAGN IMAGING, P66
  • [7] FUNDAMENTAL CORRELATION LENGTHS OF COHERENT SPECKLE IN MEDICAL ULTRASONIC IMAGES
    WAGNER, RF
    INSANA, MF
    SMITH, SW
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (01) : 34 - 44
  • [8] STATISTICAL PROPERTIES OF RADIOFREQUENCY AND ENVELOPE-DETECTED SIGNALS WITH APPLICATIONS TO MEDICAL ULTRASOUND
    WAGNER, RF
    INSANA, MF
    BROWN, DG
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (05): : 910 - 922