Novel 5′ exonuclease-based real-time PCR assay for the detection of t(14;18)(q32;q21) in patients with follicular lymphoma

被引:96
作者
Luthra, R
McBride, JA
Cabanillas, F
Sarris, A
机构
[1] Univ Texas, MD Anderson Cancer Ctr, Dept Pathol, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Cancer Ctr, Dept Hematol, Houston, TX 77030 USA
关键词
D O I
10.1016/S0002-9440(10)65546-0
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The exonuclease-based real-time polymerase chain reaction (PCR) exploits 5'-->3' exonuclease activity of Taq polymerase and measures PCR product accumulation as the reaction proceeds through a dual-labeled fluorogenic probe. The utility of this exonuclease-based PCR assay as a rapid alternative to conventional PCR for follicular lymphoma-associated t(14;18)(q32; q21) was evaluated in this study. The specificity of the assay for t(14;18) involving bcl-2 and immunoglobulin heavy-chain joining region VH) genes was assessed by analyzing DNA from 53 patients (38 B-cell non-Hodgkin's lymphomas and 15 nonneoplastic proliferations) and correlating the exonuclease PCR data with conventional PCR results. bcl-2/JH fusion sequences were detected by exonuclease-based PCR in 24 of 25 cases shown to be bcl-2 rearranged by conventional PCR. Fusion sequences were not detected in patients who were negative by conventional PCR. The overall concordance between the two assays was 98% (52 of 53 cases concordant positive or negative). In a serial dilution study using t(14;18)-positive cell line DNA, exonuclease-based PCR detected fusion sequences at DNA concentrations of 5 pg, equivalent to 0.6 to 0.8 genomes per reaction. Thus, this study demonstrated that exonuclease-based PCR for t(14;18) is both specific and highly sensitive. The elimination of the post-PCR amplicon detection steps and the ability to quantitate the input target DNA sequences make this assay ideal for routine diagnostics and monitoring minimal residual disease.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 19 条
  • [1] ASTER JC, 1992, AM J PATHOL, V141, P291
  • [2] THERMOSTABLE DNA-POLYMERASE CHAIN AMPLIFICATION OF T(14-18) CHROMOSOME BREAKPOINTS AND DETECTION OF MINIMAL RESIDUAL DISEASE
    CRESCENZI, M
    SETO, M
    HERZIG, GP
    WEISS, PD
    GRIFFITH, RC
    KORSMEYER, SJ
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1988, 85 (13) : 4869 - 4873
  • [3] Sequence-specific priming and exonuclease-released fluorescence detection of HLA-DQB1 alleles
    Faas, SJ
    Menon, R
    Braun, ER
    Rudert, WA
    Trucco, M
    [J]. TISSUE ANTIGENS, 1996, 48 (02): : 97 - 112
  • [4] A novel method for real time quantitative RT PCR
    Gibson, UEM
    Heid, CA
    Williams, PM
    [J]. GENOME RESEARCH, 1996, 6 (10): : 995 - 1001
  • [5] GRIBBEN JG, 1991, BLOOD, V78, P3275
  • [6] Real time quantitative PCR
    Heid, CA
    Stevens, J
    Livak, KJ
    Williams, PM
    [J]. GENOME RESEARCH, 1996, 6 (10): : 986 - 994
  • [7] SIMULTANEOUS AMPLIFICATION AND DETECTION OF SPECIFIC DNA-SEQUENCES
    HIGUCHI, R
    DOLLINGER, G
    WALSH, PS
    GRIFFITH, R
    [J]. BIO-TECHNOLOGY, 1992, 10 (04): : 413 - 417
  • [8] KINETIC PCR ANALYSIS - REAL-TIME MONITORING OF DNA AMPLIFICATION REACTIONS
    HIGUCHI, R
    FOCKLER, C
    DOLLINGER, G
    WATSON, R
    [J]. BIO-TECHNOLOGY, 1993, 11 (09): : 1026 - 1030
  • [9] DETECTION OF SPECIFIC POLYMERASE CHAIN-REACTION PRODUCT BY UTILIZING THE 5'-]3' EXONUCLEASE ACTIVITY OF THERMUS-AQUATICUS DNA-POLYMERASE
    HOLLAND, PM
    ABRAMSON, RD
    WATSON, R
    GELFAND, DH
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1991, 88 (16) : 7276 - 7280
  • [10] JI WZ, 1995, CANCER RES, V55, P2876