Skeletal 3-D CT: Advantages of volume rendering over surface rendering

被引:93
作者
Kuszyk, BS [1 ]
Heath, DG [1 ]
Bliss, DF [1 ]
Fishman, EK [1 ]
机构
[1] JOHNS HOPKINS UNIV HOSP, RUSSELL H MORGAN DEPT RADIOL & RADIOL SCI, BALTIMORE, MD 21287 USA
关键词
three dimensional imaging; computed tomography (CT); image processing; RECONSTRUCTION; FRACTURES;
D O I
10.1007/s002560050066
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Both surface rendering and volume rendering have been extensively applied to CT data for 3-D visualization of skeletal pathology. This review illustrates potential limitations of each technique by directly comparing 3-D images of bone pathology created using volume rendering and surface rendering. Surface renderings show gross 3-D relationships most effectively, but suffer from more stairstep artifacts and fail to effectively display lesions hidden behind overlying bone or located beneath the bone cortex. Volume-rendering algorithms effectively show subcortical lesions, minimally displaced fractures, and hidden areas of interest with few artifacts. Volume algorithms show 3-D relationships with varying degrees of success depending on the degree of surface shading and opacity, While surface rendering creates more three-dimensionally realistic images of the bone surface, it may be of limited clinical utility due to numerous artifacts and the inability to show subcortical pathology. Volume rendering is a flexible 3-D technique that effectively displays a variety of skeletal pathology with few artifacts.
引用
收藏
页码:207 / 214
页数:8
相关论文
共 16 条
[1]  
CABRAL B, 1994, P ACM IEEE S VOLUME
[2]   Volume rendering [J].
Drebin, Robert A. ;
Carpenter, Loren ;
Hanrahan, Pat .
Computer Graphics (ACM), 1988, 22 (04) :65-74
[3]   FIDELITY OF 3-DIMENSIONAL CT IMAGING FOR DETECTING FRACTURE GAPS [J].
DREBIN, RA ;
MAGID, D ;
ROBERTSON, DD ;
FISHMAN, EK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (03) :487-489
[4]   3-DIMENSIONAL IMAGING [J].
FISHMAN, EK ;
MAGID, D ;
NEY, DR ;
CHANEY, EL ;
PIZER, SM ;
ROSENMAN, JG ;
LEVIN, DN ;
VANNIER, MW ;
KUHLMAN, JE ;
ROBERTSON, DD .
RADIOLOGY, 1991, 181 (02) :321-337
[5]  
FISHMAN EK, 1993, SKELETAL RADIOL, V22, P253
[6]   SPIRAL(HELICAL) CT [J].
HEIKEN, JP ;
BRINK, JA ;
VANNIER, MW .
RADIOLOGY, 1993, 189 (03) :647-656
[7]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[8]  
KUHLMAN JE, 1988, ORTHOPEDICS, V11, P1561
[9]   DISPLAY OF SURFACES FROM VOLUME DATA [J].
LEVOY, M .
IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1988, 8 (03) :29-37
[10]  
Lorensen W. E., 1987, P 14 ANN C COMPUTER