CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: Needle size and pneumothorax rate

被引:348
作者
Geraghty, PR [1 ]
Kee, ST [1 ]
McFarlane, G [1 ]
Razavi, MK [1 ]
Sze, DY [1 ]
Dake, MD [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
关键词
computed tomography (CT); guidance; interventional procedures; complications; lung; biopsy; nodule; pneumothorax;
D O I
10.1148/radiol.2291020499
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To evaluate the effect of coaxial needle size on pneumothorax rate and the diagnostic accuracy of computed tomography (CT)-guided transthoracic needle aspiration biopsy (TNAB) of pulmonary nodules. MATERIALS AND METHODS: Retrospective review of 846 consecutive CT-guided TNAB procedures was performed. A coaxial approach was implemented in all patients by using an 18- or 19-gauge outer stabilizing needle through which a smaller aspiration needle or automated biopsy gun was inserted for tissue sampling. Univariate and multivariate regression analyses were used to analyze coaxial needle size, age, sex, smoking history, lesion size, use of an automated core biopsy gun, number of needle passes, and frequency of chest tube placement. Sensitivity, specificity, and diagnostic accuracy were calculated for 676 patients with at least 18 months of clinical follow-up. RESULTS: Pneumothorax occurred in 226 of 846 patients. Coaxial needle size and patient age had a significant effect on pneumothorax rate. Pneumothorax occurred in 124 (38%) of 324 Patients who underwent procedures with 18-gauge needles and in 121 (23%) of 522 patients who underwent procedures with 19-gauge needles (P <.001). The overall diagnostic accuracy was 96% for procedures performed with 18-gauge needles and 92% for procedures performed with 19-gauge needles, with a sensitivity of 95% and 89% and a specificity of 100% and 99%, respectively. Pneumothorax occurred in 153 patients older than 60 years, in 99 patients 60 years and younger (P <.02), in 90 patients older than 70 years, and in 162 patients younger than 70 years (P <.01). The relationship between pneumothorax rate and age as a continuous distribution was not significant (P <.07), nor were the 50- or 75-year age cutoffs (P <.06 and P <.9, respectively). CONCLUSION: Use of a smaller coaxial stabilizing needle produces a substantially decreased risk of pneumothorax with comparable diagnostic accuracy, sensitivity, and specificity for histopathologic diagnosis of pulmonary nodules. (C) RSNA, 2003.
引用
收藏
页码:475 / 481
页数:7
相关论文
共 31 条
[1]
RISK OF PNEUMOTHORAX NOT INCREASED BY OBSTRUCTIVE LUNG-DISEASE IN PERCUTANEOUS NEEDLE-BIOPSY [J].
ANDERSON, CLV ;
CRESPO, JCA ;
LIE, TH .
CHEST, 1994, 105 (06) :1705-1708
[2]
Outpatient treatment of iatrogenic pneumothorax after needle biopsy [J].
Brown, KT ;
Brody, LA ;
Getrajdman, GI ;
Napp, TE .
RADIOLOGY, 1997, 205 (01) :249-252
[3]
Transthoracic needle aspiration biopsy: Variables that affect risk of pneumothorax [J].
Cox, JE ;
Chiles, C ;
McManus, CM ;
Aquino, SL ;
Choplin, RH .
RADIOLOGY, 1999, 212 (01) :165-168
[4]
DELIUS RE, 1989, ARCH SURG-CHICAGO, V124, P833
[5]
POSTBIOPSY PNEUMOTHORAX - ESTIMATING THE RISK BY CHEST RADIOGRAPHY AND PULMONARY-FUNCTION TESTS [J].
FISH, GD ;
STANLEY, JH ;
MILLER, KS ;
SCHABEL, SI ;
SUTHERLAND, SE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (01) :71-74
[6]
PRECISE BIOPSY LOCALIZATION BY COMPUTED TOMOGRAPHY [J].
HAAGA, JR ;
ALFIDI, RJ .
RADIOLOGY, 1976, 118 (03) :603-607
[7]
COMPLICATIONS AFTER CT-GUIDED NEEDLE-BIOPSY THROUGH AERATED VERSUS NONAERATED LUNG [J].
HARAMATI, LB ;
AUSTIN, JHM .
RADIOLOGY, 1991, 181 (03) :778-778
[8]
DIAGNOSTIC ACCURACY AND COMPLICATIONS OF CLOSED LUNG BIOPSIES [J].
HERMAN, PG ;
HESSEL, SJ .
RADIOLOGY, 1977, 125 (01) :11-14
[9]
USEFULNESS OF NEEDLE-BIOPSY IN CHEST LESIONS OF DIFFERENT SIZES AND LOCATIONS [J].
JEREB, M .
RADIOLOGY, 1980, 134 (01) :13-15
[10]
Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung [J].
Kazerooni, EA ;
Lim, FT ;
Mikhail, A ;
Martinez, FJ .
RADIOLOGY, 1996, 198 (02) :371-375