Flow injection on-line group preconcentration and separation of (ultra)trace rare earth elements in environmental and geological samples by precipitation using a knotted reactor as a filterless collector for inductively coupled plasma mass spectrometric determination

被引:66
作者
Yan, XP [1 ]
Kerrich, R [1 ]
Hendry, MJ [1 ]
机构
[1] Univ Saskatchewan, Dept Geol Sci, Saskatoon, SK S7N 5E2, Canada
关键词
D O I
10.1039/a806435k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A how injection (FI) on-line filterless precipitation-dissolution system was developed for the ICP-MS determination of(ultra)trace REE in environmental and geological samples. A knotted reactor (KR), labdratory-made from PTFE tubing (200 cm x 0.5 mm id), was used as a filterless collector. On-line precipitation of REE was achieved by mixing the sample with an ammonia buffer solution. The resulting precipitates were collected on the inner walls of the KR without filtration. A flow of 1 mol l(-1) nitric acid was introduced to dissolve the collected precipitates and to transport the analyte to the ICP-MS system. Group REE preconcentration was achieved with separation from alkali and alkaline earth elements at pH 8.3-9.0. The method was demonstrated on-line with a Perkin-Elmer FIAS-400 FI system without modification. Using a preconcentration time of 120 s and a sample flow rate of 5 ml min(-1), a single preconcentration and separation with an enhancement factor of 55-75 were achieved within 5 min. The detection limits (3s) ranged from 0.06 to 0.27 ng l(-1). The precision for 16 replicate determinations of 0.1 mu g l(-1) of individual REE spiked in a porewater sample was in the range 1.8-4.2% (RSD). The accuracy of the method was demonstrated by analyzing a number of geological and environmental standard reference materials. The method was also applied to determination of ultratrace REE in porewater samples.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 42 条
[1]   Determination of the rare earth elements in aqueous samples at sub-ppt levels by inductively coupled plasma mass spectrometry and flow injection ICPMS [J].
Aggarwal, JK ;
Shabani, MB ;
Palmer, MR ;
Ragnarsdottir, KV .
ANALYTICAL CHEMISTRY, 1996, 68 (24) :4418-4423
[2]   NATURAL ANALOG STUDIES - GEOLOGY AND MINERALOGY OF MORRO DO FERRO, BRAZIL [J].
BARRETTO, PMC ;
FUJIMORI, K .
CHEMICAL GEOLOGY, 1986, 55 (3-4) :297-312
[3]   DETERMINATION OF TRACE-METALS IN REFERENCE WATER STANDARDS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH ONLINE PRECONCENTRATION [J].
BEAUCHEMIN, D ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1857-1862
[4]   FLOW-INJECTION MANIFOLDS WITH MEMBRANE FILTERS FOR PRECONCENTRATION AND INTERFERENCE REMOVAL BY PRECIPITATION FLOW-INJECTION FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
DEBRAH, E ;
ADEEYINWO, CE ;
BYSOUTH, SR ;
TYSON, JF .
ANALYST, 1990, 115 (12) :1543-1547
[5]   DETERMINATION OF TRACE-METALS IN CONCENTRATED BRINES USING INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY ONLINE PRECONCENTRATION AND MATRIX ELIMINATION WITH FLOW-INJECTION [J].
EBDON, L ;
FISHER, A ;
HANDLEY, H ;
JONES, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (07) :979-981
[6]   PRECONCENTRATION AND PURIFICATION OF RARE-EARTH ELEMENTS IN NATURAL-WATERS USING SILICA-IMMOBILIZED 8-HYDROXYQUINOLINE AND A SUPPORTED ORGANOPHOSPHORUS EXTRACTANT [J].
ESSER, BK ;
VOLPE, A ;
KENNEALLY, JM ;
SMITH, DK .
ANALYTICAL CHEMISTRY, 1994, 66 (10) :1736-1742
[7]  
Fang Z., 1995, FLOW INJECTION ATOMI
[8]   FLOW-INJECTION ONLINE COPRECIPITATION PRECONCENTRATION FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, ZL ;
DONG, LP .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :439-445
[9]   FLAME ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF LEAD IN BIOLOGICAL SAMPLES USING A FLOW-INJECTION SYSTEM WITH ONLINE PRECONCENTRATION BY COPRECIPITATION WITHOUT FILTRATION [J].
FANG, ZL ;
SPERLING, M ;
WELZ, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (04) :301-306
[10]  
GOVINDARAJU K, 1994, GEOSTANDARD NEWSLETT, V18, P1