Supercritical fluid chromatography with electrochemical detection of phenols and polyaromatic hydrocarbons

被引:19
作者
Dressman, SF [1 ]
Simeone, AM [1 ]
Michael, AC [1 ]
机构
[1] UNIV PITTSBURGH,DEPT CHEM,PITTSBURGH,PA 15260
关键词
D O I
10.1021/ac951188l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A self-contained electrochemical cell consisting of a working and a counter electrode coated with a thin poly-(ethylene oxide) film containing lithium triflate has been evalulated as an on-line detector for supercritical fluid chromatography, Electrochemical detection of 11 priority phenols and 13 polyaromatic hydrocarbons separated on a packed diol column with neat and methanol-modified CO2 mobile phases is described. The detector is operated voltammetrically, which permits the simultaneous detection of both oxidizable and reducible components of individual mixtures. Quantitative aspects of the detector performace have been evaluated and compared to those of a downstream flame ionization detector. The electrochemical detector provides low-nanogram detection limits and responds linearly over two decades of injected quantities. An advantage of voltammetric detection is the selectivity derived from the range of applied potentials used. Overlapping elution profiles of chloro-, methyl-, and nitro-substituted phenols can be resolved voltammetrically by capitalizing on differences between their half-wave potentials. The detector can be used for a period of at least 3 days without refurbishing, The electrochemical detector is compatible with CO2 containing 1% (v/v) methanol, which can be used to decrease the total analysis time for the phenol mixture from 50 min in unmodified CO2 to 20 min.
引用
收藏
页码:3121 / 3127
页数:7
相关论文
共 28 条
[1]   SIMULTANEOUS DETERMINATION OF 27 PHENOLS AND HERBICIDES IN WATER BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH MULTIELECTRODE ELECTROCHEMICAL DETECTION [J].
ACHILLI, G ;
CELLERINO, GP ;
DERIL, GM ;
BIRD, S .
JOURNAL OF CHROMATOGRAPHY A, 1995, 697 (1-2) :357-362
[2]   SUPERCRITICAL FLUID EXTRACTION AS A SAMPLE INTRODUCTION METHOD FOR CHROMATOGRAPHY [J].
ANDERSEN, MR ;
SWANSON, JT ;
PORTER, NL ;
RICHTER, BE .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (07) :371-377
[3]  
BARD AJ, 1978, ENCY ELECTROCHEMISTR, V12, P181
[4]   EXPERIMENTAL-DESIGN APPROACH FOR THE EXTRACTION OF POLYCYCLIC AROMATIC-HYDROCARBONS FROM SOIL USING SUPERCRITICAL CARBON-DIOXIDE [J].
BARNABAS, IJ ;
DEAN, JR ;
TOMLINSON, WR ;
OWEN, SP .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2064-2069
[5]   SELECTIVE INHIBITION OF ELECTRODE REACTIONS BY ORGANIC COMPOUNDS .1. INHIBITION OF BR2 AND I2 EVOLUTION ON PLATINUM BY PHENOL [J].
BEJERANO, T ;
FORGACS, C ;
GILEADI, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1970, 27 (01) :69-&
[6]   SEPARATION OF PHENOLS BY PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
BERGER, TA ;
DEYE, JF .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (02) :54-59
[7]  
BRUDZEWSKI J, 1993, AM FAM PHYSICIAN, V47, P623
[8]   POLAROMICROTRIBOMETRIC STUDY OF POLYPHENYLENE OXIDE FILM FORMATION ON METAL-ELECTRODES BY ELECTROLYSIS OF DISUBSTITUTED PHENOLS [J].
BRUNO, F ;
PHAM, MC ;
DUBOIS, JE .
ELECTROCHIMICA ACTA, 1977, 22 (04) :451-457
[9]   ANALYSIS OF VOLATILE ORGANICS BY SUPERCRITICAL-FLUID EXTRACTION COUPLED TO GAS-CHROMATOGRAPHY .1. OPTIMIZATION OF CHROMATOGRAPHIC PARAMETERS [J].
BURFORD, MD ;
HAWTHORNE, SB ;
MILLER, DJ .
JOURNAL OF CHROMATOGRAPHY A, 1994, 685 (01) :79-94
[10]   SELECTIVE DETERMINATION OF PHENOLS IN WATER BY A 2-TRAP TANDEM EXTRACTION SYSTEM FOLLOWED BY LIQUID-CHROMATOGRAPHY [J].
DICORCIA, A ;
MARCHESE, S ;
SAMPERI, R .
JOURNAL OF CHROMATOGRAPHY, 1993, 642 (1-2) :175-184